background image

 

CleanTech 2000S / 4000S Boot Sanitizing Pan

 

Automated Handwashing & Boot Sanitizing System 

 

 

INSTALLATION AND OPERATION MANUAL

 

 
 
 
 
 

 

Manufactured by:

  

Meritech Systems, LLC 

720 Corporate Circle, Suite K 

Golden, CO 80401 USA 

 

Phone: (800) 932-7707 

Fax: (303) 790-4859 

 

www.meritech.com

  

E-mail: 

[email protected]

 

 
 
 

 
 
 

 

 

WARNING:  The performance and effectiveness of CleanTech® systems have been 

extensively tested when using solutions provided by Meritech Systems, LLC.  

Satisfactory performance or effectiveness cannot be guaranteed when other solutions 

are used.  

 

FAILURE TO USE MERITECH SYSTEMS, LLC SUPPLIED  

CHEMICALS WILL VOID ANY AND ALL WARRANTIES 

 

 
 

January 1, 2020 

 

Содержание CleanTech 2000S

Страница 1: ...CleanTech 2000S 4000S Boot Sanitizing Pan INSTALLATION AND OPERATION MANUAL ...

Страница 2: ...800 932 7707 Fax 303 790 4859 www meritech com E mail service meritech com WARNING The performance and effectiveness of CleanTech systems have been extensively tested when using solutions provided by Meritech Systems LLC Satisfactory performance or effectiveness cannot be guaranteed when other solutions are used FAILURE TO USE MERITECH SYSTEMS LLC SUPPLIED CHEMICALS WILL VOID ANY AND ALL WARRANTIE...

Страница 3: ...ITIZING PAN Installation and Operation Manual Description Page Index 3 Introduction 4 Overview 5 6 Facility Installation Instructions Requirements 7 10 First Time Start Up Operation 11 Cycle Time Calibration 12 System Cleaning 12 13 Contacting Meritech 13 ...

Страница 4: ...an will fit into an area that accommodates 23 width X 42 depth footprint and will hook up to your existing standard hot cold water lines and wall drain for the handwasher However in addition you will need a floor drain for the boot pan A more detailed description of the installation procedure can be found in the Installation Guide of this manual The CleanTech 4000S w Boot Sanitizing Pan will fit i...

Страница 5: ... Quick water inlet disconnect for cleaning 2 simple slide on drain hoses for the floor drain Sloped ramps for safety Highly visible caution markings for safety Equipped with an easy re prime button to refill the pan after cleaning or startup Interior rubber footwear mat available in various heights to control water depth o 5 8 mat will provide 1 8 solution depth standard street shoe o mat will pro...

Страница 6: ...6 CleanTech 4000S w Boot Sanitizing Pan ...

Страница 7: ...l source for future serviceability of the system A floor drain is required for the Boot Sanitizing Pan to function properly Do not hard pipe the drain fittings as this prevents easy removal and cleaning of the pan 1 Install the 2000S system per its installation instructions 2 Unpack the boot pan and place in front of the 2000S per the photo below 3 Make certain that the pan is sitting level and do...

Страница 8: ...ct to the fitting on the bottom left side of the system See photos below Make certain the supply line is pushed at lease 3 8 in to the fitting 6 Take the opposite end of the supply line and attach it to the pan manifold See photo on next page ...

Страница 9: ...nual gives detailed instruction on the installation operation cleaning of the Boot Sanitizing Pan Do not hardwire the system electrical cord without having a way to disconnect the system from electrical source for future serviceability of the system A floor drain is required for the Boot Sanitizing Pan to function properly Do not hard pipe the drain fittings as this prevents easy removal and clean...

Страница 10: ...SURE ABOUT THE INSTALLATION PROCEDURE WE ENCOURAGE YOU TO CONSULT IMMEDIATELY WITH MERITECH SYSTEMS LLC Meritech Systems LLC 720 Corporate Circle Suite K Golden CO 80401 USA Phone 800 932 7707 Fax 303 790 4859 www meritech com E mail service meritech com ...

Страница 11: ...3 Press and hold the prime button for 20 seconds allowing the water and the Self Clean solution to fill the pan to its normal water height based on the mat purchased 4 Using a Quat test stripe 0 1000 ppm check the concentration of the pan The concentration in the pan should be 800 1000 PPM 5 The CleanTech system with the boot pan is then ready for use 6 Once hands are placed into the cylinders the...

Страница 12: ...rocess should also be documented within your HAACP or SSOP procedures and or per your company s internal procedures Meritech recommends daily cleaning of the system as well as the Boot Sanitizing Pan Please refer to the CleanTech Maintenance Manual or request the specific cleaning instructions from Meritech customer service Boot Sanitizing Pan Cleaning Instructions 1 Carefully and slowly lift the ...

Страница 13: ...as needed Contact Meritech Customer Service for additional assistance on cleaning assistance or instruction on any systems manufactured by Meritech Contacting Meritech If you have questions about the general use of the CleanTech systems need installation or trouble shooting assistance or need to purchase additional solution for your system contact us below Meritech Systems LLC 720 Corporate Circle...