Meridian Manufacturing, Inc.
October 2014 | Revision 1.0
9-8
NOTICE
To avoid contaminating the DEF solution and
possible nozzle malfunction, keep the nozzle clean.
Always store the nozzle in the nozzle holder when
not in use.
2.
Extend the DEF hose to easily reach the fill
opening of the machinery being serviced.
CAUTION
Once the pump is turned ON, the DEF hose is
pressurized and will pump DEF solution. Do
not squeeze the handle on the nozzle until it
is inside the DEF tank of the machinery being
serviced.
3.
Turn the power switch to the ON position to
start the DEF pump.
4. Fill the machine’s DEF tank. Once the DEF
tank is filled, turn the pump OFF. Do not run
the pump any longer than necessary.
SAFETY
INSTRUCTIONS
Even though nozzle (2) is equipped with an auto-
matic shutoff, do not leave the nozzle unattended
during filling. Be prepared to manually shut off flow
at the nozzle, if necessary.
5. Replace the nozzle in its holder.
Note:
If the hose is extended to its limit, it may not
retract. Should this occur, grasp the reel
and rotate it towards you until it clicks. The
hose will then retract normally.
Chapter 9 | Operation