![Merak MEP2L Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/merak/mep2l/mep2l_manual_1771299065.webp)
Configuration
COMMAND LIST
CALLS
OF ALARM
PROG CONS
COMMENTS
Alarm button B1
press time to
generate alarm
call
*10#n *10*
Time between the alarm
button being pressed and
the alarm being activated:
n=0-9 seconds
Default value = 3
No. of attempts
ringing
alarm
*20#n *20*
Number of alarm call
attempts to the same
number: n=1-3
Default value = 1
Start end of
alarm call
*99#
From the alarm reception
equipment: 1) type *99# to
start end of alarm call and
2) key in *90# to
acknowledge end of alarm.
See example D
Alarm reset
*90#
CALLS
OF TEST
PROG CONS
COMMENTS
Identifier
*3#n
*3*
Assign a number to identify
the lift in test calls: n=8
digits.
Number of test
call attempts
*21#n *21*
Number of test call
attempts to the same
number: n=1-3
Default value = 1
Test call period
*24#n *24*
The final 4 digits represent
the time in minutes: n=1-4
digits
Default value: 4320
minutes (every 3 days)
Time until next
test call
*33*
Check the time remaining
until the MEP2L makes the
next test call.
Force test call
*95#
Activate a test call
27
MEP2L M3.0-S1.4 EN
2020 Merak Telsis SL. All rights reserved
Содержание MEP2L
Страница 2: ...MANUAL Tel fono de emergencia para ascensores www merak es MEP2L M3 0 S1 4 ES 01 2020 EN 81 28...
Страница 9: ...9 Instalaci n MONTAJE M4 MEP2L M3 0 S1 4 ES 2020 Merak Telsis SL Todos los derechos reservados M4...
Страница 37: ...www merak es Merak Telsis S L Avda Sarri 67 bis E 3 08029 Barcelona Telf 34 933631428 Email info merak es...
Страница 38: ...MANUAL Emergency phone for lifts www merak es MEP2L M3 0 S1 4 EN 01 2020...
Страница 45: ...7 Installation MOUNTING MEP2L M3 0 S1 4 EN 2020 Merak Telsis SL All rights reserved M4...