Parameter 22 sets the management
mode concerning EN 81-28.
Parameter 22 Default value is 2
Configuration
ALARM VOICE CALL MANAGEMENT
Par
22
EN 81-28
Mode
ACK
Manage
ment
EOA
Manage
ment
0
NO
NO
NO
1
YES strict
YES
YES
2*
Practical
YES
NO
•
Basic Phone (Mode 0):
No call
confirmation from the rescue center is
required by the press of a key (ACK),
nor are activated alarm signals or final
alarm (EOA) managed. This mode does
not comply with EN 81-28.
•
EN 81.28 Mode strict (Mode 1):
Alarm
call confirmation ACK is required by
pressing the 3 key from the rescue
center for the call to be valid, activated
alarm signal and EOA signal are
managed. Requires manually EOA
canceling.
•
Practical EN 81-28 mode (Mode 2):
Alarm call confirmation ACK is required
by pressing the 3 key from rescue
center for the call to be valid. No alarm
signals or EOA are managed.
•