Mendota MEDALLION Скачать руководство пользователя страница 3

 

 

You are the owner of a world class heat producing gas direct vent sealed combustion stove. 

This elegant, highly efficient Stove will be a constant source of comfort and fascination.  It will be the focal point of 
beauty and interest in your home. 

The Mendota Gas Stove is a true heating appliance incorporating the traditional aesthetics of stove fire viewing with 
the controllability and fuel efficiency of a home gas furnace. Of particular interest is the low fuel consumption and 
brilliant fire viewing afforded by the patented realistic HearthGlo wood fire-like combustion system. 

Carefully read the following instructions prior to actual installation.  Proper Mendota Gas Stove installation and 
operation will give you years of safe trouble free comfort and enjoyment. 

If you have any questions regarding installation or operation of your Mendota Stove please contact your local dealer. 

......CAUTION..... 

FOR YOUR SAFETY do not install or operate your Mendota Gas Freestanding Stove without first reading and 
understanding this manual.  Any installation or operational deviation from this manual voids the Mendota Gas Stove 
Warranty and may prove hazardous! 

Due to high temperatures, the Stove should be located out of traffic and away from furniture and draperies.  Children 
and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or 
clothing ignition. Young children should be carefully supervised when they are in the same room as the Mendota Gas 
Stove. 

Clothing or other flammable material should not be placed on or near the Stove. 

The Mendota Gas Stove is a powerful, efficient heating unit.  It has been designed as a major source of supplemental 
heat. As with any mechanical appliance there can be component shut downs.  It is advisable to have an alternate 
(back-up) heat supply. 

Installation, repair and any adjustments to logs or burner must be done by a qualified service person.  The Stove 
should be inspected before use and at least annually by a professional service person.  More frequent cleaning may 
be required due to excessive lint from carpeting, bedding material, carbon build-up, etc.  It is imperative that control 
compartments, burners and circulating air passageways of the appliance be kept clean.  The burner and pilot flames 
and logs should be visually checked periodically. 

DO NOT use this Stove if any part has been under water or exposed to moisture corrosion.  Immediately call a 
qualified service technician to inspect the Stove and replace any part of the control system and any gas control which 
has been under water.  DO NOT use this Stove if the burner does not light immediately.  Turn unit off and call 
Mendota approved service person if there is any delay in burner light-off. 

It is Johnson Gas Appliance Company's policy that no responsibility is assumed by the Company or by any of its 
employees or representatives for any damages caused by an inoperable, inadequate, or unsafe condition which is the 
result, either directly or indirectly, of any improper operation, installation or servicing procedures. 

Building Permit and Installation Inspection Approval Requirements 

All installations of Mendota Fireplace and Inserts must comply with all the 

requirements stated in this Installation and Operating Instructions Manual.  
The Dealer and/or installer must also obtain all required Building Permits 
and Inspection Approval from the local building inspection department or the 
local body having jurisdiction. 

In order to validate warranty coverage, Mendota may require facsimile 
copies of the Building Permit and Inspection Approval forms.  Failure to 

provide adequate proof that the installation conforms to all local requirements and the requirements stated in the 
Installation and Operating Instructions Manual will void all applicable warranty. 

INSTALLER:  THESE INSTRUCTIONS ARE TO REMAIN WITH HOMEOWNER. 

 

2

Содержание MEDALLION

Страница 1: ...TINGUISH ANY OPEN FLAME 5 IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE 6 FOLLOW THE GAS SUPPLIERS INSTRUCTIONS 7 IF GAS SUPPLIER IS UNAVAILABLE CALL YOUR FIRE DEPARTMENT DO NOT STORE OR...

Страница 2: ...AL TOTAL WEIGHT 225 LB SAFETY AGA CERTIFIED PILOT GENERATOR MILLIVOLT THERMOCOUPLE SYSTEM ACTIVATED WITH SWITCH OR THERMOSTAT GAS REQUIREMENTS SUPPLY PRESSURE NAT GAS 7 W C 5 W C MIN 11 W C MAX L P GA...

Страница 3: ...on repair and any adjustments to logs or burner must be done by a qualified service person The Stove should be inspected before use and at least annually by a professional service person More frequent...

Страница 4: ...ant Si aucun code n existe suivez la norme ANSI Z223 1 ou la norme CAN CGA ACNOR B149 _______________________________________________ MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION Unit to sidewall...

Страница 5: ...urce of supplemental heat Air movement options for maximizing heat circulation which can be considered are through the wall grills or floor grills or the continuous operation of central heating blower...

Страница 6: ...MENDOTA MEDALLION MENDOTA DIRECT VENT FREESTANDING GAS STOVE SPECIFICATIONS CLEARANCES Figure 2 Specifications Clearances 5...

Страница 7: ...ss window door by releasing the 4 turn latches behind side doors rotate latches counterclock wise and pull outward and carefully sliding glass door forward 4 You are now ready to hook up the gas suppl...

Страница 8: ...Vertical clearance to ventilated soffit located above the terminal from the center line of the terminal 18 inches 46 cm minimum K Clearance to a mechanical air supply inlet 6 feet 1 8 m minimum E Cle...

Страница 9: ...rate vent system Common vent systems are prohibited Do not recess vent termination into a wall or siding WE STRONGLY RECOMMEND THAT FIXED LENGTH PIPE SECTIONS BE USED IN PLACE OF TELESCOPING SECTIONS...

Страница 10: ...Galvanized 36 RIGID VENT STACK PIPE Black 48 RIGID VENT STACK PIPE Galvanized 48 RIGID VENT STACK PIPE Black 11 14 5 8 ADJUSTABLE VENT PIPE Black Only 2 90 ELBOW Galvanized 90 ELBOW Black 3 45 ELBOW G...

Страница 11: ...ypes of venting system installations A HORIZONTAL THROUGH THE WALL TERMINATION 1 Minimum rise 2 Elevated rise B VERTICAL THROUGH THE ROOF TERMINATION 1 Through typical roof 2 Through existing chimney...

Страница 12: ...pendicular to the wall The height of the opening must be located to meet all local and national building codes and not allow the termination to be easily blocked or obstructed If wall being penetrated...

Страница 13: ...system is attached If this is the case you may want to adjust the stove location 2 Locate position where vent pipe will pass through any ceilings and will penetrate the outside wall Since vent pipe s...

Страница 14: ...rilled hole placed in the roof in No 1 The opening should be a sufficient size to meet all clearance requirements Continue to assemble lengths of pipe and elbows necessary to reach the Ceiling Support...

Страница 15: ...tangular hole for the Support Box Cut the hole 1 8 larger than the Support Box outline Lower the Support Box through the hole in the roof until the bottom of the Support Box protrudes at least 2 inche...

Страница 16: ...through the center of the chimney system and center the Adapter on the top of the chimney pipe Drill 4 1 8 diameter holes through the Adapter and into the chimney top Insure that you are in fact drill...

Страница 17: ...2 1 3cm 5 8 1 6cm 1 2 1 3cm 40 100 1 2 1 3cm 1 2 1 3cm 3 4 2 0cm 1 2 1 3cm 100 150 3 4 2 0cm 1 2 1 3cm 7 8 2 3cm 5 8 1 6cm 150 200 3 4 2 0cm 1 2 1 3cm 7 8 2 3cm 3 4 2 0cm NOTE Some areas allow copper...

Страница 18: ...r s capacity is not sufficient to add the Gas Stove an additional inches to inches regulator must be installed for the Stove EXCEPTION Some codes allow 2 PSI 1 4KPA supplies to enter the residence in...

Страница 19: ...t be installed in accordance with instructions and local and national codes LIGHTING CHECK OFF LIST All items on Installation Check Off List see above must be completed If thermostat or remote control...

Страница 20: ...s in place cycle the burner again to make sure of prompt ignition of burner that flame runs smoothly around burner and does not lift off burner NOTE Flames may not come through coals until glass is in...

Страница 21: ...Log Fire View Figure 9 Log Module 2 0...

Страница 22: ...Carefully unpack one piece log assembly and center on log rest between Side Log Tabs Place log assembly over front locating pins 5 Place glowing embers wool sparsely on top coals in front of front lo...

Страница 23: ...ER DOES NOT COME ON IMMEDIATELY AFTER SECOND TRY RECHECK COMPLETE INSTALLATION OF LOGS PILOT ETC TO INSURE PROPER PILOT FLAME IMPINGEMENT ON THE THERMOPILE AND PROMPT BURNER IGNITION NEVER TURN BURNER...

Страница 24: ...in gas pressure B Carbon dirt or lint Have your gas supplier check for correct gas 7 W C Nat Gas 11 W C LP Gas If flame still needs adjustment see Flame Adjustment below Clean out carbon spider webs...

Страница 25: ...ves that are put in gas both natural and propane to make it smell can be harmful to glass and can leave a white film deposit on the glass This deposit can be removed with cleaners such as KEL KEM Poli...

Страница 26: ...side 7 18 50 01 00017 Pop Rivet 1 8 x 1 4 Aluminum WARNING Use only authorized parts and materials obtained from Johnson Gas Appliance when replacing defective or damaged glass DO NOT substitute other...

Страница 27: ...illivolt generation and assure trouble free burner operation Readings must be taken with a Pilot ONLY operating b Main Burner operating A PILOT ONLY OPERATING Thermostat OFF Minimum Millivolts 325 Usi...

Страница 28: ...e pg 20 for location Orifice is removed and installed with a deep well socket and ratchet 2 Install pilot orifice 05 04 00036 014 see pg 28 for location Remove and install pilot hood with 7 16 open en...

Страница 29: ...K 45 01 00101 908B STACK 6 RIGID VENT BLACK 45 01 00098 911B 11 14 ADJUSTABLE PIPE 45 01 00148 917B ADJUSTABLE PIPE 17 24 BLACK 45 01 00143 945BG ELBOW 45 DEG SWIVEL BLACK 45 01 00142 945G ELBOW 45 DE...

Страница 30: ...Piezo Igniter 65 14 00050 Main Orifice L P Gas 50 35 01 00239 Ember Wool 65 06 00435 Metallic Black Paint Spray Can 05 07 00061 Thermopile 50 06 00065 Door Latch 05 07 00067 Thermocouple 50 06 00064...

Страница 31: ...urer s specifications INSTALL PROPER SIZE GAS LINES CHECK FOR GAS LEAKS Per Manual CHECK FOR CORRECT GAS PRESSURE AT MANIFOLD Per Manual a 3 5 Inches Water Column Maximum Nat Gas b 10 5 Inches Water C...

Страница 32: ...TAPE SHUT POSTAGE NEEDED JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 3 1...

Страница 33: ...NOTES NOTES 3 2...

Страница 34: ...MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY MENDOTA MEDALLION SDV40 DIRECT VENT GAS STOVE 3 3...

Страница 35: ...warranted against burn out Mendota has the right to investigate and inspect the exact original stove and entire installation without any alterations or tampering in the event a claim is made to determ...

Страница 36: ...Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 WEBSITE www johnsongas com 0405 Part 85 03 00701...

Отзывы: