The following Check Off Lists must be completed prior to final operation of the Stove, or
manufacturer's warranty and liabilities will be voided:
INSTALLATION CHECK OFF LIST
Co-axial vent rigid pipe, wall vent cap or roof vent cap must be installed by a
Mendota approved person in accordance with instructions. All joints must be
secured, "twist-locked" and leak-proof.
Horizontal or vertical vent cap must be installed "
right-side-up
" and tightly
sealed to structure per instructions. Vent Caps must be Mendota approved Do not
recess vent cap into the wall or siding.
Proper exterior and interior clearances for vent systems and locations for wall
vent cap/roof vent cap must be maintained (See pages 8-16).
Carefully check for correct gas pressure, proper size gas lines (see page 17 & 18)
and for gas leaks.
115 V electrical service and gas supply must be installed in accordance with
instructions and local and national codes.
LIGHTING CHECK OFF LIST
All items on "Installation Check Off List" (see above) must be completed.
If thermostat or remote control is used, connect to terminals on rear of stove
pedestal.
System millivolt readings (see Pg. 27) must be taken by a qualified installer.
CAUTION: Pilot flame must register a minimum of 460 millivolts.
Check air shutter opening - 1/8" to 1/4" Nat. gas or 1/2" LP gas (see page 24).
Carefully follow all Lighting and Log Installation Instructions.
Make certain that burner lights immediately and flame runs promptly around
"curve" in burner and lights entire burner.
DO NOT proceed with operation unless burner cycles "on/off" without delays.
Make certain that the flame is "stable" and does not "lift" off burner. If flame
lifts off burner, turn unit off and check that all vent pipes are "twist locked" and
leak proof and vent cap is "right side up".
DO NOT proceed with operation if flame is "lifting off" burner.
Insure proper placement of logs and coals (See Pg. 22).