LIGHTING INSTRUCTIONS
IMPORTANT:
Be sure all items on "LIGHTING CHECK OFF LIST" [Pg. 19] have been completed!
CAUTION
: If the pilot goes out, be sure to wait a minimum of five minutes before relighting - be sure to always
remove the glass before relighting the pilot.
1. Remove Glass door assembly. - ALWAYS LIGHT
PILOT WITH GLASS REMOVED!
2. Make sure any gas supply shut-off cocks are open and
On-Off Switch or thermostat is "OFF".
3. Push in Gas Cock Dial slightly and turn clockwise to
"OFF". NOTE: Dial cannot be turned from "PILOT"
to "OFF" unless dial is pushed in slightly. DO NOT
FORCE!
FIGURE 8: Gas Valve
4. Wait five [5] minutes to allow gas which may have
accumulated in main burner compartment to escape.
If you smell gas STOP!
5. Turn Gas Cock Dial Counterclockwise to "PILOT" position [See FIGURE 8].
6. Depress Gas Cock Dial and push in red Piezo igniter button. Once pilot ignites, continue depressing dial for
about 1/2 minute. If pilot does not remain ignited, repeat operation allowing a longer period before releasing
Gas Cock Dial.
IMPORTANT:
After pilot is lit, Millivolt readings & gas pressure should be taken by qualified installer.
Pilot flame must register a minimum of 325 millivolts [See Pg. 27].
7. After pilot is lit and before installing logs, turn Gas Dial and Rocker Switch to "ON" and "cycle" the burners
on/off to make certain they ignite promptly and that the flame runs smoothly around entire burner.
NOTE:
Logs will produce a strong acrid odor on initial contact with flames (about 2 hrs.).
8. With pilot operating, install logs and coals [See Pg. 22]. With logs/coals in place, "cycle" the burner again to
make sure of prompt ignition of burner, that flame runs smoothly around burner and does not "lift off" burner.
NOTE
: Flames may not come through coals until glass is installed and logs are "hot" (approx. 10 Min.). To
make final flame color adjustment wait 15-20 minutes, with glass installed. [See Pg. 26].
9. Reinstall glass. In daily operation, always light burner with glass in place.
10. When heat or a log fire is desired, turn Gas Dial counterclockwise to "ON". Rocker Switch, Thermostat or
Remote Control must also be turned "ON".
11. Main burner should now light IMMEDIATELY and flame should not "lift off" burner. If there is any delay in
ignition or if flame is "lifting off" burner, turn off burners and carefully check for proper installation of
logs/coals, proper pilot flame impingement on burners and thermopile, proper vent system installation. Logs and
coals must not block pilot flame or main burner flame. Vent pipes must be leak proof.
DO NOT PROCEED WITH OPERATION UNLESS BURNERS "CYCLE" ON/OFF WITHOUT DELAYS!
12.
To reduce heat output, turn Hi/Lo Knob counterclockwise to desired temperature [See FIGURE 8].
NEVER "over fire" by increasing BTUH above nameplate specifications.
NEVER turn down pilot flame below the required 325 millivolts.
13.
Open windows for first two hours of operation.
Notice: Initial start-up will cause some NON-TOXIC "off gassing" of adhesives, binders, paint, etc. Most nuisance odors will be
eliminated after the first 2 hrs. of operation, however, slight amounts may be present during the first 24 hrs.
SHUT DOWN PROCEDURE:
1. Turn Rocker Switch, Remote Control or Thermostat to "OFF". Pilot will remain lit for return to normal service.
2. For complete shutdown turn Rocker Switch and Gas Cock Dial [FIGURE 8] to "OFF".