8
14.
Remove Slide Adapter Boot as shown:
15.
Tightly secure 3” and 4” flex vents with clamps provided. Seal vent cap/flashing to top of chimney
with weatherproof sealer. Seal areas between flex pipes and existing chimney, at damper area,
with unfaced fiberglass insulation.
16.
Carefully slide Insert into the fireplace opening (Note: Plug in the blower to a 110 volt AC recep-
tacle inside the fireplace opening, if so equipped).
Re-engage Slide Adapter and re-install keeper plate as shown:
c.
Remove self tapping hex head
screws
.
b.
Remove key plate
Slide Adapter tab
a.
Disengage Slide Adapter
by sliding rearward
.
a.
Slide Insert
into fireplace
c.
While sliding Insert inward, using the
Latch Tool, pull the Slide Adapter out-
ward, to re-engage on to Insert top.
b. Engage Latch Tool
into adapter tab here.
d. Re-install key
plate and screws.