13
GAS LEAK TEST REQUIREMENT:
It is the responsibility of the installer/service person to
assure that each and every gas connection and supply tubing that are a part of this fireplace
are leak proof. The qualified/ certified individual connecting the gas supply line, performing
pressure tests or performing any service to this fireplace is required to perform a THOROUGH
LEAK TEST on ALL gas fittings that are a part of this appliance or the gas supply line connec-
tion using soap-water solution or a calibrated combustible gas detector. Failure to perform
this leak test may lead to a house fire and/or an explosion. Mendota is not responsible for any
damages due to an Installer’s failure to conduct a leak test and verify that all connections and
supply lines are leak proof.
WARNING: Do not operate appliances with glass front removed, cracked, or broken.
Replacement of glass should be done a licensed or qualified service person.
Note: Consult the local or national installation code(s) to assure that adequate combus-
tion and ventilation air is available.
HIGH ALTITUDE INSTALLATIONS
For installations from 610-1370 meters (2000-4500 ft.) the orifice sizes (DMS) for natural
gas are #47 Front/#39 rear and for propane gas are #57 front/#54 rear. See data plate
for additional information. For high altitude installations consult the local gas distributor or
the authority having jurisdiction for proper rating methods. If the installer must convert
the unit to adjust for varying altitudes, the information sticker must be filled out by the in-
staller and adhered to the appliance at the time of conversion.
«Cet appareil est equipé pour des altitudes compries entre 0 et 2000 pieds (0-610 m)
seulement»
This appliance has been converted for use at an altitude of ______________
Orifice size _______________
Manifold Pressure ________________
Input (Btu/h)_______________ Fuel Type _______________________
Date of conversion _________ Converted by _____________________
«Cet appreeil a été converti au ____
Injecteur ________
Pression à la tubulure d'alimentation _____________
Déoit calorifique _______________»