INSTALLATION CHECK OFF LIST
The following check list must be completed prior to initial lighting of the Fireplace
Insert, or manufacturer's warranty and liabilities will be voided:
Venting system must be installed by a Mendota approved person according to Figure
3, Pg.
Error! Bookmark not defined.
with clamps securely in place and all joints
leak proof.
Electrical supply and gas supply must be properly installed and must conform to Na-
tional and Local Codes.
Check that correct fuel supply is connected to appliance. Check correct gas pressure,
correct size gas lines and for gas leaks on all gas supply connectors and this gas in-
sert’s gas valve train connectors.
Proper clearances to combustibles must be maintained.
LEAK TEST REQUIREMENT
: Vibration during shipping and transit of this appliance
may cause some gas connections to loosen. All gas train connections in this ap-
pliance, including field installed supply line fittings and all factory installed gas train
connections between the gas valve and the burner orifice(s) and pilot light, must be
leak tested prior to first firing using soap and water solution or a calibrated Combusti-
ble Gas Detector. All leak tests are to be performed by a qualified installer. It is the
responsibility of the installer to verify that all connections are sealed properly and leak-
proof.
LIGHTING CHECK OFF LIST
Be sure to check these items before final operation of the Fireplace Insert
All items on "Installation Check Off List" must be completed.
Connect Rocker Switch, Wall Switch, Remote Control or Thermostat to main valve.
Carefully follow all lighting and log installation instructions. Make certain that burner
lights immediately and lights both front and rear burners.
DO NOT proceed with operation unless burner cycles "on/off" without delays and the
flame is "stable" and not "lifting" off burner.
Caution: If pilot goes out be sure to wait a minimum of 5 minutes before relighting.