22
LIGHTING INSTRUCTIONS
IMPORTANT:
Be sure all items on "LIGHTING CHECK OFF LIST" [Pg. 14] have been completed!
1. Make sure any gas supply shut-off cocks are open.
IMPORTANT:
Be sure all items on “INSTALLATION CHECK OFF LIST” (PG. 30 ) have been completed!
CAUTION:
If the pilot goes out, be sure to wait a minimum of five minutes before relighting.
3.
Make sure any gas supply shut-off cocks are open.
5. Locate battery box on left side of insert opening (Remove glass door as shown on Pg# to gain
access to battery box. Slide out box, remove Phillips screw and cover. Install 4 AAA batteries.
6. Install a 9 volt battery into the back side of remote control:
7. Ignite pilot with remote control as follows:
Simultaneously press the "OFF" and UP ARROW buttons, until an audible "BEEP" is heard.
This starts a timing sequence during which a series of "BEEPS" is heard:
When beeping stops, the pilot flame should be lit. If there is no pilot, wait 5 minutes, and repeat
this step. If it still does not light, refer to the MERTIK MAXITROL troubleshooting information in-
cluded with these instructions. After beeping stops, the main burner will automatically ignite on
the high setting - after a few seconds.
Press and release both but-
tons to begin ignition se-
quence.
Note: After beginning igni-
tion sequence, the remote
defaults to the “TEMP”
(thermostat) mode. To
change to the “Manual”
mode, simply push the UP or
DOWN arrow.