18
DXV DOOR OPERATION
TO REMOVE DOOR
1.
Place both thumbs on lower doorframe directly above Spring Loaded Door Holding Bar.
2.
Reach fingers under Bar and pull Bar straight out from Fireplace front.
3.
Pull Bar down and move bar inward until bar clears doorframe - then release.
4.
Repeat procedure for opposite Holding Bar.
5.
Carefully lift door straight up until doorframe "clears" the 3 Door Holding Tabs on top of firebox.
6.
Pull door directly out from firebox front
TO REPLACE DOOR
1.
Center door in firebox opening. Move door inward until the 3 slots on doorframe are directly above
the 3 Door Holding Tabs on firebox top.
2.
Lower door so the 3 Tabs on firebox top fit through the 3 slots on the doorframe.
(i.e. "Hang" door on the 3 Tabs)
3.
"Swing in" the lower edge of door until it touches lower firebox front.
4.
Pull Holding Bar down and outward (away from Fireplace) until it clears doorframe.
5.
Raise Bar until it fits securely in Bar Holding Brackets on doorframe.
6.
Repeat procedure for opposite Holding Bar.
CAUTION: Holding Bars MUST be "level" and securely in place on Bar Holding Brackets holding glass door
TIGHTLY against firebox front. The spring-loaded door is a pressure relief safety system and
must be positioned as shown.
WARNING: DO NOT OPERATE THIS APPLIANCE WITH THE GLASS REMOVED, CRACKED OR BROKEN.
REPLACEMENT OF GLASS SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON.