28
14.
To reduce heat output, turn Hi/Lo Knob counterclockwise to desired temperature (see FIGURE 5: Gas Valve).
Heat output can be reduced to 23,000 BTUH using the Hi-Lo Control. NEVER "over fire" by increasing BTUH
above nameplate specifications. NEVER turn down (reduce) pilot flame below the minimum 250 millivolts.
15.
To reduce the flame and heat down to 6500 BTUH., use the rocker switch (see step 7) to turn off rear burner.
NOTE: The rear burner is controlled by a 9 Volt DC solenoid valve. One 9 Volt battery (located behind the Bat-
tery Compartment cover) provides power for this unique feature. Replace with a new high quality 9 volt battery
annually.
16.
Open windows for first two hours of operation.
NOTICE: Initial heater start-up will cause some NON TOXIC "off gassing" of adhesives, gasket binders, paint and other materials. Most
nuisance odors will be eliminated after the first two hours of operation; however, slight amounts may be present during first 24 hours of
initial operation
. To eliminate all nuisance odors, continuously operate this fireplace on the HIGH setting for 8 to 12
hours.
SHUT DOWN PROCEDURE:
1. Turn Remote Control or Thermostat to "OFF". Pilot will remain lit for return to normal service.
2. For complete shutdown turn Gas Cock Dial (see FIGURE 5: Gas Valve) to "OFF".
WARNING:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.
4.