1
HIGH ALTITUDE INSTALLATION INFORMATION
: Prior to installing at altitudes higher than 7500, please con-
tact the Mendota technical service department for specific venting requirements and venting restrictions.
TABLE OF CONTENTS
LOCATING THE FIREPLACE AND GENERAL INFORMATION
3
SPECIFICATIONS & CLEARANCES
4
INSTALLATION INSTRUCTIONS
5
GAS SUPPLY REQUIREMENTS
6
GAS PRESSURE REQUIREMENTS
7
EXTERIOR VENTING LOCATIONS AND RESTRICTIONS
8
FLUE VENTING INSTRUCTIONS
9
FLUE VENTING REQUIREMENTS
10
FLUE VENTING COMPONENTS
11
MINIMUM RISE THROUGH-THE-WALL VENTING
12
ELEVATED THROUGH-THE-WALL VENTING
13
VERTICAL THROUGH-THE-ROOF VENTING
14
DESIGNER FRONTS INSTALLATION INFORMATION AND CAUTIONS
16
GLASS DOOR OPERATION
18
COAL BED AND LOGS INSTALLATION
19
INSTALLATION & LIGHTING CHECK OFF LISTS
26
LIGHTING INSTRUCTIONS
27
THERMOSTAT OR REMOTE CONTROL OPERATION
29
BLOWER & BURNER REMOVAL& INSTALLATION-BLOWER WIRING
30
TROUBLE SHOOTING - MAIN BURNER GAS FLAME ADJUSTMENT
31
CUSTOMER INFORMATION AND TROUBLE SHOOTING
32
MAINTENANCE
33
NATURAL TO LP CONVERSION
34
REPLACEMENT PARTS
36
WARRANTY QUALIFICATION AND REGISTRATION FORM
36
WARRANTY
39
SPECIFICATIONS
MENDOTA, MODEL DXV-45
High Fire - Adjustable to - Low Fire
BTUH. (MODEL DXV-45)
NAT. GAS
45,000
7,500
BTUH. (MODEL DXV-45)
L.P. GAS
40,000
5,000
NOTE: LP CONVERSION KIT #HA-42-00072 MUST BE PURCHASED SEPARATELY FOR THE DXV-45 FIREPLACE
TO BURN LPG. SEE PG. 34 FOR INSTALLATION INSTRUCTIONS.
MAIN ORIFICE:
MAIN BURNER #36 NAT. GAS-#53 L.P. GAS – FRONT BURNER #44 NAT. - #3/64 LP
OVERALL EFFICIENCY
....................
EXCEEDS D.O.E. EFFICIENCY REQUIREMENTS (A.F.U.E.) FOR DIRECT VENT
WALL HEATERS
CO-AXIAL DIRECT VENT FLUE ..... 5" INNER, 8" OUTER
TOTAL WEIGHT ................................. 205 POUNDS
SAFETY ................................................ AGA CERTIFIED PILOT GENERATOR, MILLIVOLT SYSTEM
ACTIVATED WITH SWITCH, THERMOSTAT OR REMOTE CONTROL.
GAS REQUIREMENTS ........................ SUPPLY PRESSURE:
GAS INLET: 3/8" N.P.T.
NAT.
GAS:
7" W.C.
(5" W.C. MIN., 11" W.C. MAX.)
L.P.
GAS:
11.0" W.C.
(11" W.C. MIN., 13" W.C. MAX.)
ELECTRICAL REQUIREMENTS ....... 120 VOLT
APPROVED VENT SYSTEMS: AMERIVENT, DURAVENT, SELKIRK METALBESTOS, SECURITY CHIMNEY
Certified under ANSI Z21.88-2002•CSA 2-33-2002 and CAN/CGA 2.17 M91. DXV-45 is also deemed in compliance with
ANSI Z21.50•CSA 2.22 2000“Vented Gas Fireplace Heaters" not for use with solid fuel. Approved for bedroom installations
and mobile homes. UL307B approved for "mobile homes, after first sale of home, not for recreational vehicles." “Gas-fired
appliances for use at high altitudes.”