33 

 
 

MAINTENANCE 

1.

 

ANNUAL MAINTENANCE OF MENDOTA UNITS IS REQUIRED

.  The following procedures must be per-

formed each year by a Mendota approved service person.  NOTE:  Any adjustments to burner, pilot or logs must be 
done by a qualified Mendota service person. 

A.

 

Clean all lint and dust built-up around the control.  Inspect the condition of any wiring under the burner for melt-
ing or damage. 

B.  Remove logs & coals and clean away any foreign matter (lint, carbon, etc.) on the burner and logs.  Be sure the 

burner ports are "open".  Clean the pilot and under side of the logs for any carbon deposits.  NOTE:  Logs should 
be visually checked for carbon "build-up".  If carbon deposits are visible on logs, unit should be turned off and 
Mendota service person contacted.  Be sure logs are re-installed per instructions on page 

Error! Bookmark not 

defined.

C.  Make sure hot air outlet grills are free from lint and other obstructions.  Never block or obstruct grill openings.  

Check condition of gaskets, gaskets must be tight, replace if necessary. 

D.  Check that chimney flue and outlet are open and free of blockage. 

E.

 

Before re-installing glass, have qualified service person check the operation of the pilot with millivolt meter and 
cycle the burner per LIGHTING INSTRUCTIONS (see pg. 27).  Pilot must read a minimum of 250 millivolts.  Be 
sure all items in LIGHTING and INSTALLATION "check off " lists are completed (see pg. 24). 

F.

 

Before re-installing glass, have qualified service person check for door gasket condition and proper seal.  If gasket 
is deteriorated or does not seal properly, replace door gasket. 

2. 

COMBUSTION SYSTEM MILLIVOLT READING: 

Millivolt readings must be taken by a qualified installer at the time of installation and after any interruption in burner 
operation.  These readings will establish proper thermopile millivolt generation and assure trouble-free burner opera-
tion.  Readings must be taken with:  a.)  Pilot ONLY operating. 

  b.)  Main Burner operating. 

A. 

PILOT ONLY OPERATING  -  

Thermostat "OFF"  -  Minimum Millivolts 250 

Using a Millivolt Meter, a millivolt reading should be taken by attaching Meter leads to terminals #1 and #2 on 
the main gas valve.  The Meter must read a minimum of 250 millivolts with the Pilot Light operating, Thermo-stat 
turned "OFF" and Main Burner "OFF".  To increase or decrease millivolts, (and pilot flame) adjust pilot screw on 
control (see 

Figure 8

).

 

 

B. 

MAIN BURNER OPERATING  -  

Thermostat "ON" - Minimum Millivolts 100  

Using a Millivolt Meter a millivolt reading should be taken by attaching Meter leads to terminals #2 and #3 on the 
millivolt panel on the main gas valve.  The Meter must read a minimum of 100 millivolts with the Gas Cock Dial 
turned “ON”, Thermostat "ON" and Main Burner operating.  To increase or decrease millivolts (and pilot flame) 
adjust pilot screw on control (see 

Figure 8:  Millivolt Readings

).

 

 

CHECK 

TEST 

TO TEST 

CONNECT 

METER 

LEADS TO 

TERMINALS 

THERMOSTAT 

CONTACTS 

METER 

READING 

SHOULD BE 

COMPLETE 

SYSTEM 

2 & 3 

CLOSED 100MV 

OR 

MORE 

THERMO- 

PILE 

OUTPUT 

1 & 2 

OPEN GREATER 

THAN 

325 MV 

SYSTEM 

RESISTANCE 

1 & 3 

CLOSED 2.75 

OHMs 

MAX 

AUTO/ 

PILOT 

DROPOUT 

1 & 2 

OPEN BETWEEN 

120-30 MV 

3. 

THE VIEWING GLASS SHOULD BE CLEANED 
PERIODICALLY.

  Exterior glass may be cleaned with cleaner as desired.  Interior glass - use KEL KEM  "Polish 

Plus" or comparable product.  Do Not use oven cleaner or abrasive cleaners to clean glass.  DO NOT CLEAN WHEN 
GLASS IS HOT. 

 
4. 

PERIODIC VISUAL CHECK OF BURNER AND PILOT FLAMES IS REQUIRED

 

Figure 8:  Millivolt Readings 

Содержание DXV-45 Deep Timber III

Страница 1: ...T TRY TO LIGHT ANY APPLIANCE 4 EXTINGUISH ANY OPEN FLAME 5 DO NOT USE THE PHONE IN YOUR BUILDING 6 IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE 7 FOLLOW THE GAS SUPPLIERS INSTRUCTIONS 8...

Страница 2: ...ION AND REGISTRATION FORM 36 WARRANTY 39 SPECIFICATIONS MENDOTA MODEL DXV 45 High Fire Adjustable to Low Fire BTUH MODEL DXV 45 NAT GAS 45 000 7 500 BTUH MODEL DXV 45 L P GAS 40 000 5 000 NOTE LP CONV...

Страница 3: ...e an alternate heat supply Installation repair and any adjustments to logs or burner must be done by a qualified service person The Fireplace should be inspected before use and at least annually by a...

Страница 4: ...a large area of your home if situated to maximize heat circulation Air movement options for maximizing heat circulation which can be considered are through the wall grills or floor grills the continuo...

Страница 5: ...higher than 7500 please con tact the Mendota technical service department for specific venting requirements and venting restrictions DXV 45 GAS DIRECT VENT FIREPLACE SPECIFICATIONS CLEARANCES DIRECT...

Страница 6: ...ed on the top of this fireplace The Top Screw Strip provides a 4 clearance to combustible materials at the top of the fireplace See Page 4 for specific details Combustible wall covering materials may...

Страница 7: ...ual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 PSIG 3 5 kPa The proper gas line diameter must be selected to run from...

Страница 8: ...Gas Fireplace an additional inches to inches regulator must be installed for the Fireplace EXCEPTION Some codes allow 2 PSI 1 4KPA supplies to enter the residence in which case pounds to inches regula...

Страница 9: ...ance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 inches 30 cm minimum D Vertical clearance to ventilated soffit located above the terminal from...

Страница 10: ...ng separate solid fuel or gas burner appliance Each direct vent gas appliance must have its own separate vent system Common vent systems are prohibited To assure proper venting performance of the high...

Страница 11: ...REQUIREMENTS FOR NG AND LPG NOTE IF A 90 ELBOW IS CONNECTED DIRECTLY TO THE FLUE OULET THE MAXIMUM HORIZONTAL DISTANCE FROM THE FLUE OUTLET CENTERLINE TO THE OUTSIDE WALL IS 24 A MAXIMUM OF THREE 3 90...

Страница 12: ...VANIZED ELBOW 5 8 4 45 01 00229 ADJUST WALL THIMBLE 5 8 5 45 01 00226 11 14 ADJUSTABLE PIPE 5 8 9 45 01 00239 ATTIC INSULATION SHIELD 12 5 8 10 45 01 00236 ROOF FLASHING 0 12 TO 6 12 5 8 10 45 01 0023...

Страница 13: ...wall 3 Cut and frame a 10 3 4 x 10 3 4 opening in the outside wall The hole must be positioned so the vent sys tem will run level or have a rise AND be perpendicular to the wall The height of the open...

Страница 14: ...through any ceilings and will penetrate the outside wall Since vent pipe sections overlap we suggest pre assembling and measuring the total vent pipe run so you can more accurately locate the point wh...

Страница 15: ...o assemble lengths of pipe and elbows ne cessary to reach up through the roofline Galvanized pipe and elbows may be utilized in the attic as well as above the roofline The galvanized finish is desirab...

Страница 16: ...l service department for specific venting requirements and venting restrictions 8 Height H of top of vent cap can be determined as follows 9 Complete installation with storm collar and vent cap H DIME...

Страница 17: ...nts The Andover Door and Prairie Door Fronts are designed to be Full Face trim kits These two Fronts cover an area equivalent to that shown in the diagram below Any material that protrudes into this a...

Страница 18: ...Grills Victoria Filigrees and Tuscany Filigrees The Millenia Flat Grills Victoria Filigree and Tuscany Filigree are designed to be inside fit trim kits All of these trim kits fit within the inner peri...

Страница 19: ...Holding Tabs on firebox top 2 Lower door so the 3 Tabs on firebox top fit through the 3 slots on the doorframe i e Hang door on the 3 Tabs 3 Swing in the lower edge of door until it touches lower fire...

Страница 20: ...L BED AND LOGS INSTALLATION Carefully unpack the shipping boxes containing the coal bed sections and logs and remove them gently from the foam packing Note Each coal bed and log is lettered on its und...

Страница 21: ...20...

Страница 22: ...21...

Страница 23: ...22...

Страница 24: ...23...

Страница 25: ...24...

Страница 26: ...rison to the diagram below and if any flames are floating off the burner surface after 10 minutes of starting the fireplace turn off the fireplace and contact your installer or fireplace dealer Have t...

Страница 27: ...national codes LIGHTING CHECK OFF LIST All items on Installation Check Off List see above must be completed Connect thermostat to terminal panel next to gas valve per instructions on pg 27 Perform Le...

Страница 28: ...dule and coals see pg 20 With logs coals in place cycle the burner again to make sure of prompt ignition of burner and that the flame runs smoothly around entire burner NOTE Logs will produce a strong...

Страница 29: ...volt battery annually 16 Open windows for first two hours of operation NOTICE Initial heater start up will cause some NON TOXIC off gassing of adhesives gasket binders paint and other materials Most...

Страница 30: ...nit lights DO NOT push button and release quickly before burner lights Burner should light IMMEDIATELY and then button can be released If unit does not light imme diately release button wait 60 second...

Страница 31: ...egulated with the rheostat included but it must be on at all times the burner is on NOTE There will be a time delay in blower operation during heat up approx hour and extended blower operation during...

Страница 32: ...r should be removed by qualified person and the air shutter opening checked to be cer tain that the shutter is set correctly at 1 8 to 1 4 open for Natural gas and 1 2 minimum open for L P gas NOTE Fo...

Страница 33: ...odically Exte rior glass may be cleaned with cleaner as desired Interior glass use soap and water Kel Kem Glass Cleaner or equivalent NOTE Additives that are put in gas both natural and propane to mak...

Страница 34: ...olt readings must be taken by a qualified installer at the time of installation and after any interruption in burner operation These readings will establish proper thermopile millivolt generation and...

Страница 35: ...33 below Identify the pressure regulator spring that is located in the center of the black rubber gasket Discard both the black rubber gasket and spring 3 Install the new LP Pressure Regular onto the...

Страница 36: ...35 Figure 10 Figure 9 LP PRESSURE REGULATOR NG PRESSURE REGULATOR GAS VALVE BODY SCREWS...

Страница 37: ...NITER 35 01 00311 LARGE CHUNK COALS 05 07 00061 THERMOPILE 35 01 00304 EMBER FLOOR SET 05 01 00118 THERMOSTAT Wall Mount 10 03 00068 REAR FLAME WIRING W SWITCH 05 01 00157 SNAP DISC FAN TEMP SENSOR 05...

Страница 38: ...Orifice 0 610 m Orifice Front 44 Rear 35 Front 3 64 Rear 52 Orifice 610 1370 m Orifice Front 45 Rear 35 Front 3 64 Rear 53 Maximum output Btu hr Sortie maximale 32 400 28 800 Manifold Pressure in w c...

Страница 39: ...table pipe sections CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES VENT LOCATIONS Per Manual INSTALL PROPER SIZE GAS LINES CHECK FOR GAS LEAKS Per Manual CHECK FOR CORRECT GAS PRESSURE AT MANIFOLD Per Ma...

Страница 40: ...39 TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY POSTAGE NEEDED...

Страница 41: ...any part of this limited warranty Mendota has the right to investigate and inspect the exact original Fireplace and entire installation without any alterations or tampering in the event a claim is ma...

Страница 42: ...41 Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Mendota Hearth Division www johnsongas com or www mendotahearth com 0406 Part 65 05 00090...

Отзывы: