40
TEMPERATURE INDICATOR (
o
F or
o
C)
1.
Press the ON/OFF Key and Turn Off the Fireplace.
2.
Simultaneously, Press both the MODE Key and the Thermostat
Key.
3.
Look at the LCD display to verify that your desired indicator (
o
F or
o
C) is being displayed. If not, repeat step 2.
KEY LOCK FUNCTION
To prevent unsupervised children from operating the fireplace, a KEY LOCK function is pro-
vided with this remote control system. To activate the KEY LOCK function, simultaneously
press the “MODE KEY” and the “UP KEY”. To deactivate the KEY LOCK function, simulta-
neously press the “MODE KEY” and the “UP KEY”.
During KEY LOCK mode, none of the Keys will function. You must DEACTIVATE the sys-
tem before you can use the Remote Transmitter.
LOW BATTERY POWER DETECTION
1.
Transmitter Batteries
: The life span of the remote control transmitter batteries depends
on various factors: quality of the batteries used the number of ignitions of the appliance,
the number of changes to the room thermostat set point, etc. When the Transmitter bat-
teries are low, a Battery Icon will appear on the LCD display of the Transmitter before all
battery power is lost. When the batteries are replaced, this icon will disappear.
OPERATING DURING POWER OUTAGES
This electronic ignition system utilizes the supplied 120VAC power when it is available for all functions of this system. If the
AC power is interrupted during a power outage, install batteries in the battery pack (supplied with this fireplace on the right
side of Courtesy Panel).
During the power outage, the appliance’s burners will function. In addition, Flame Height adjustment and Secondary Burn-
er ON/OFF functions will be available. The Fan and Accent Light, which are wholly dependent on 110VAC power, will not
function.
The fireplace is designed to operate during power outages for 1-1/2 continuous hours, Maximum. The blower will
not operate, but natural convection can be improved by removing the upper grill and opening the screen doors
(depending on the type of optional front installed). After 1-1/2 continuous hours of operation, during the power
outage, turn off the burners for 1 hour and allow the fireplace to cool down. Consecutive 1-1/2 hour burn and 1
hour cool down cycles are allowed.
Содержание DT3-PF2-LX
Страница 6: ...5...
Страница 37: ...COMPLETED LOG SET ASSEMBLY...
Страница 59: ...58 RATING LABEL REPRESENTATION DXV35 DT3...
Страница 60: ...59 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 61: ...60 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 63: ...62 TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED...