DXV35 DT3 FEATURES - QUICK REFERENCE INFORMATION
EXTERNAL DIMENSIONS
: 35-7/8” Wide X 31-1/2” High X 15-1/2” Deep
MINIMUM FRAMING DIMENSIONS
: 37-1/8” WIDE x 31-1/2” HIGH X 16” DEEP
GLASS SIZE
: NeoCeram Glass with non-reflective coating. Visible Glass measures 456 in
2
. Actual Glass size is 580 in
2
.
MANTEL ALLOWANCE
: 8” Deep Mantel at 14” Above Top Convection Opening
VENT SYSTEM ALLOWANCE
: Top Vent Only. 12” Vertical Minimum with 6” max horizontal. 55 feet Vertical Maximum.
4” exhaust and 6-5/8” combustion air intake coaxial vent pipe required. 12’ maximum horizontal run allowed with 4’ mini-
mum vertical starter section.
VENT DAMPER ADJUSTMENT AVAILABLE
: There is one exhaust vent damper included in this unit and located in the
top convection chamber at the center.
CONTROLS
: IPI Electronic Ignition System with AC Primary Power and DC Backup Power. Accent light and Blowers op-
erate on AC Power only. Thermostatic Remote Control Transmitter with Smart Thermostat Mode.
BLOWER SYSTEM
: 210 CFM Dual Blower System. 120VAC, 2Amps. Dedicated Hot Power only. No switches, Fan Speed
Controls or Light Dimmers are allowed in same circuit.
Accent Light System
: Accent Light System Included. Light can be turned on or off or dimmed using dimmer mounted
behind lower grill. Accent Light can also be turned on or off using Remote Control Transmitter.
BURNER SYSTEM
: Dual 304 Stainless Steel Tubular burners.
BURNER AIR SHUTTER SYSTEMS
: Externally controllable Rear Burner air shutter and Internal rotary Front Burner air
shutter.
LOG SET
: 9-piece, Premium Definition Log Set with Extreme glow and realism ember bed.
REFRACTORY PANELS
: High Detail Red Clinker Fiber Brick Panels included. Brick Panels required for operation.
NATURAL GAS INFORMATION
: Factory equipped for Natural Gas. 4.5”WC Minimum inlet pressure required. For NG
applications, Front Burner Orifice Size is #49 and the Rear Burner Orifice Size is #44.
LPG INFORMATION
: LP conversion kit #HA-30-00507 is required. 12”WC Minimum inlet pressure required. For the
DXV35 DT3 LPG application, both front are rear burner orifices are to be drill size 3/64”. For higher altitude, adjustment to
orifice size may be necessary.
INITIAL STARTUP ADVICE
PAINT CURING CYCLE RECOMMENDATION
: It is recommended that you run this Fireplace on maximum flame height,
for 3 cycles of 2 hours ON and 2 hours OFF, initially, to cure the paint.
BLOWER BREAK-IN PERIOD
: The integrated blowers in this Insert may exhibit some bearing noise and electrical static
noise during the first few days of operation. This is normal during the break-in period. It is recommended that following the
Paint Curing Cycle, the blowers be run at their maximum speed for two 3-hour periods. The burner flames must be on dur-
ing these cycles. The blowers in a few fireplaces may take longer to break-in and may require additional operation time
before all extraneous noise is eliminated. Please allow adequate operational time for the blowers to break-in before you
contact your dealer for service.
Содержание DT3-PF2-LX
Страница 6: ...5...
Страница 37: ...COMPLETED LOG SET ASSEMBLY...
Страница 59: ...58 RATING LABEL REPRESENTATION DXV35 DT3...
Страница 60: ...59 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 61: ...60 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 63: ...62 TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED...