38
BEFORE YOU BEGIN
Read this entire manual before you use your new fireplace (especially the section “Safety Precautions” on page 2). Failure
to follow the instructions may result in property damage, bodily injury, or even death.
An Optional Wall Holder (#HA-78-00205) for the Remote Transmitter is available. Contact you dealer.
Remote Control Transmitter Functions
NOTE
: The Receiver will “beep” once every time a
Remote Transmitter Key is pressed, signaling that the
command has been received.
Identify the four function buttons on the Remote
Transmitter:
1.
ON/OFF KEY
: This button turns
the system ON or OFF. When
this button is pressed and the
system is OFF, the pilot light
will stay ON if the “Standing Pilot Switch” is in
the ON position.
2.
THERMOSTAT KEY
: This button, when pressed after the ON/OFF KEY is pressed and the
system is ON, will allow the selection of three modes: Manual Operation, Normal Thermostat
and Smart Thermostat.
1.
Manual Mode
: In this mode, the room temperature is ignored and the fireplace can be turned ON indefinitely.
The room temperature rise has no effect on this mode. All other functions such as fan speed control, flame
height control, secondary burner On/OFF control and Accent Light ON/OFF controls will be manually control-
lable.
2.
Normal Thermostat
: In this mode, the fireplace will
stay functioning until the room temperature in-
creases 1
o
F above the Set Point Temperature. To
increase the Set Point Temperature, Press the UP
button until the desired temperature is displayed in
the SET POINT TEMPERATURE window. The fan
will turn on 5 minutes after fireplace startup and will
turn off 12-1/2 minutes after the flames turn off, in
this mode. The flame height can be adjusted while
the fireplace is functioning, fan speed can be ad-
justed after 5 minutes of startup. Secondary burner
can be turned On or Off at any time after startup.
The Accent Light can be turned on or off any time
after startup.
3.
Smart Thermostat
: In this mode, all other func-
tions except the flame height adjustment are allowed. Manual flame height adjustment is not allowed in this
mode. The Smart Thermostat function adjusts the flame height in accordance to the difference between the
set point temperature and the actual room temperature. As the room temperature gets closer to the set point
temperature, the Smart Function automatically modulates the flame down.
3. UP/DOWN KEY:
This key is used to increase or decrease the Set Point Temperatures, Flame
Height and Fan Speed and to toggle between Accent Light ON/OFF and Secondary Burner
ON/OFF
.
4. MODE SELECTION KEY:
This key is used to toggle between the various function icons : Flame
Height, Fan Speed, Accent Light Dimmer and Secondary Burner On/Off.
SMART
ON
OFF
SMART
MODE
NORMAL
THERMOSTAT
MANUAL
MODE
68
Hi
MAX
MAX
Hi
OFF
76°
F
F
76°
ON
SMART
76°
F
Содержание DT3-PF2-LX
Страница 6: ...5...
Страница 37: ...COMPLETED LOG SET ASSEMBLY...
Страница 59: ...58 RATING LABEL REPRESENTATION DXV35 DT3...
Страница 60: ...59 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 61: ...60 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 63: ...62 TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED...