Malfunctions, warning and error messages
6.3 Power failure
Warning!
Depending on the operation performed, the surfaces in the interior
and the chamber load may still be very hot after power loss. Ad-
ditionally, depending on the duration of the power loss, the appli-
ance might heat up again after power supply has been restored (see
below). Touching these surfaces can cause burns. Wear heat-resistant
OQNSDBSHUDFKNUDRNQV@HSTMSHKSGD@OOKH@MBDBNNKRCNVMÅQRS
In case of a power failure, the appliance operates as follows:
In manual mode
After power supply has been restored, operation is continued with the parameters set. The
time and the duration of the power failure is documented in the protocol log memory.
In timer mode
In case of an interruption of the power supply of less than 60 minutes, the current timer is
continued from the point at which it was interrupted. For interruptions of the power supply
longer than this, all appliance functions (heating, fan etc.) are switched off and the air flap is
opened.
In remote control mode:
The previous values are restored.