FOCKE MELER GLUING SOLUTIONS
6-6
TROUBLESHOOTING
Causes
Checking
Comments
Actions
Temperature sensor
malfunction.
Check the sensor
resistance (Pt-100 or Ni-
120) with polimeter.
Check CN1 connector (sensor board)
and the two bottom wires status.
Change connector.
Change sensor.
Sensor wrong
positioned.
Check the sensor position
inside its housing.
Sensor must be introduced to the
bottom.
Introduce sensor to the
bottom.
Sensor board
malfunction.
Last failure option.
Check first sensors, connections and
wirings.
Change sensor board.
Temperature fluctuations in the manifold/ manifolds
The manifold does not stop heating (Micron, 2 geared motores)
Causes
Checking
Comments
Actions
Power board
malfunction.
Check the power board.
LED indicator DL
(*)
remains off.
(4 )
Change power board.
Control board
malfunction.
Check the control board.
LED indicator DL
(*)
remains on.
(5)
Change control board.
Note
Manifold 1
Manifold 2
(1)
F4
F5
(2)
Pin 1 y 2 / DL3
Pin 4 y 5 / DL5
(3)
Pin 1 y 2
Pin 4 y 5
(4)
DL3
DL5
(5)
DL3
DL5
(*)
To differentiate between manifold 1 and 2.
Causes
Checking
Comments
Actions
An element has not
reached the required
temperature.
Check the temperature on
all heated devices.
Refer to the previous sections ‘tank,
distributor, hose and applicator‘.
Wait or repair the faulty
device.
(*)
In units with 2 motors, if no pumping operations are carried out due to a faulty device, both motors will not operate.
The pump control board has been switched off
Melter does not pump
Problems associated with temperatures
Causes
Checking
Comments
Actions
Faulty pump control
board fuse.
Remove the fuse from
the board and check for
continuity.
If there is continuity in the fuse, it is
OK.
Replace the fuse.
Faulty pump control
board.
Check the voltage on
connector E1 of the board.
If there is 24 VDC and the board does
not switch on, the board is not OK.
Replace the pump control
board.
Faulty power supply.
Check that the power supply
(5V1) receives 230 V and has
an output of 24 V. Check
that there are 24 V in E1.
If the output is not 24 V, the power
supply is not OK.
Replace the power supply.
Содержание Micron 5
Страница 1: ...ADHESIVE MELTER MICRON GEAR SERIES INSTRUCTIONS MANUAL MA 5079 ENG 200718 GLUING SOLUTIONS ...
Страница 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 36: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 4 34 MELTER OPERATION This page is intentionally left blank ...
Страница 80: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Страница 94: ...FOCKE MELER GLUING SOLUTIONS 6 14 TROUBLESHOOTING This page is intentionally left blank ...
Страница 102: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 106: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...