![Meler Micron 5 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/meler/micron-5/micron-5_instruction-manual_1767103021.webp)
INTRODUCTION
2-7
MA-5079-ENG
MICRON GEAR ADHESIVE MELTER
(1)
In case of simple pump up to 6 outputs but in case of double pump up to 4.
(2)
The 230°C version and the version with the tank lid featuring gas or dry air
intake do not allow the use of float detectors.
(3)
In the case of two single pumps or two double pumps, place a 2 before
the pump type (SX or DX). In the case of one single pump and a double pump,
place the single pump (SX) first followed by the double pump (DX). The
maximum number of pumps is two per equipment.
Micron gear range option accessories
If some of the different machine configuration options have been chosen, it
will be necessary to purchase the following accessories:
Automatic feeder option
The automatic adhesive loader must be requested separately and is the same
for the 5, 10, 20 and 35l machines.
Micron gear series range
Micron
5 /
2
M01
200
BE
S8
V
A0
PC
LD2
B0
Micron series
tank capacity -
5: 5kg / 10: 10kg / 20: 20 kg / 35: 35 kg
no. electric outputs
(1)
-
2 / 4 / 6
temperature sensor type -
M01: Pt100 / N01: Ni120
type of pump -
BE: gear
maximum temperature
(2)
-
200: 200°C / 230: 230°C
type of pump
(3)
-
S: simple / D: double
cover model - CG: automatic feeder
/
V: standard / G: standard with gas inlet
air dryer system -
A0: no dryer system / A1: air dryer system
bypass valve pressure control system -
PC: pneumatic reg. / MC: mechanic reg.
low level detector - LD0: no detector
LD1: floating-type det. / LD2: capacitive det.
low level warning light -
B0: no warning light / B1: with warning light
Содержание Micron 5
Страница 1: ...ADHESIVE MELTER MICRON GEAR SERIES INSTRUCTIONS MANUAL MA 5079 ENG 200718 GLUING SOLUTIONS ...
Страница 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 36: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 4 34 MELTER OPERATION This page is intentionally left blank ...
Страница 80: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Страница 94: ...FOCKE MELER GLUING SOLUTIONS 6 14 TROUBLESHOOTING This page is intentionally left blank ...
Страница 102: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 106: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...