![Meler Micron 5 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/meler/micron-5/micron-5_instruction-manual_1767103049.webp)
MELTER OPERATION
4-13
MA-5079-ENG
MICRON GEAR ADHESIVE MELTER
Timer to switch between ON - Standby - OFF modes
This function is used to program automatic switching from the ON mode to
Standby mode after an inactive period of time (S-1) and from STANDBY mode
to OFF mode after another waiting period (S-2) during which activity has not
been resumed.
To program this function and ensure that it works properly, the melter must be
connected to the main unit via the CN4 external standby connector on the con-
trol board. The main unit will use this connection to send continuous signals
(not less than 500 ms) indicating that production is in progress. After the first
programmed time elapses without any activity (S-1) the equipment will switch
to STANDBY mode. If the equipment remains in standby and the ‘Standby’
push button is not pressed during the second programmed time (S-2), the
equipment will switch to OFF mode.
To set the equipment to the ON mode again, press the ‘ON/OFF’ push button
on the control board. The programmed S-1 time will begin a countdown the
moment the melter reaches the service temperature.
S-1
S-2
Functionality
dIS
dIS
The external Standby input (CN4) is disabled. The melter can be set to
Standby mode with the push button.
OFF
OFF
The external Standby input (CN4) runs normally.
• Contact CLOSED: Equipment in STANDBY Mode.
• Contact OPEN: Equipment in ON Mode.
Between 001 and
999 (minutes)
OFF or 000
The external Standby input (CN4) detects inactivity.
If no activity is taking place, once the time programmed in S-1 elapses,
the melter switches from ON mode to OFF mode.
It will not switch to STANDBY mode because S-2 is OFF or 000.
Between 001 and
999 (minutes)
Between 001 and
999 (minutes)
The Standby input (CN4) detects inactivity.
If no activity is taking place, once the time programmed in S-1 elapses,
the melter switches from ON Mode to STANDBY Mode.
If no activity is taking place, once the time programmed in S-2, elapses
the melter switches from STANDBY Mode to OFF Mode.
ON Mode
STANDBY Mode
OFF
Part
Part
Part
Part
Part
Part
Production in the main unit
S-1
S-2
Содержание Micron 5
Страница 1: ...ADHESIVE MELTER MICRON GEAR SERIES INSTRUCTIONS MANUAL MA 5079 ENG 200718 GLUING SOLUTIONS ...
Страница 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 36: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 4 34 MELTER OPERATION This page is intentionally left blank ...
Страница 80: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Страница 94: ...FOCKE MELER GLUING SOLUTIONS 6 14 TROUBLESHOOTING This page is intentionally left blank ...
Страница 102: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 106: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...