FOCKE MELER GLUING SOLUTIONS
INSTALLATION
3-6
Once the pump operation has been checked, you may adjust the pressure to
the operational value you wish.
In the pressure gauge can be found pneumatic and hydraulic pressure values,
the relation between both are 1:13.
Warning: A 6 bar on the grid, the maximum pressure on the hydraulic circuit
reaches 80 bar. There is a risk of burns or particle projection. Use thermal
protective gear and goggles.
Hose and applicator connection
These series melters use standard Meler components. The entire range of
Meler hoses and applicators may be connected to this equipment.
Up to six hose-applicator outputs may be connected to 5, 10, 20 and 35L Mi-
cron gear melters.
Micron gear series melters are equipped with a simple hydraulic distributor
with four posibilities of hydraulic connection and double hydraulic distributor
up to eight positions to connect the hoses. The outputs are not numered so the
hoses can be connected to the distributor in any order.
Warning:
When connecting hose-applicator outputs, verify that the connected
power is not above the maximum allowable power for each output.
Caution:
• It is preferable to use couplings at 45º and 90° angle to minimize the
space the hoses occupy. Using straight couplings usually results in
curves with very small radii that may damage the inside of the hose.
• Save the screw-on caps that are removed from the distributor in order
to connect a hose. They may be necessary in the future if a hose is
removed from its location.
• Perform the electrical hose and applicator connections with the
equipment turned off. Failing to do so may result in electrical defects in
the connection and the appearance of alarm messages on the melter
display.
Parameter Programming
Once the melter and its components are installed, you will need to program
the operational parameters appropriate for the specific application that will be
performed.
Micron gear series simplify this task as much as possible, allowing the
operator to modify only those parameters that are necessarily variable for
each application.
Among the various parameters, it is necessary to program the set point
temperature values for each component connected and the value for
overheating warnings. There are two other parameters (weekly start-up and
shut-down programming and the standby temperature value) left to program
1
2
4
6
3
5
Ø6mm
Содержание Micron 5
Страница 1: ...ADHESIVE MELTER MICRON GEAR SERIES INSTRUCTIONS MANUAL MA 5079 ENG 200718 GLUING SOLUTIONS ...
Страница 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 36: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 4 34 MELTER OPERATION This page is intentionally left blank ...
Страница 80: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Страница 94: ...FOCKE MELER GLUING SOLUTIONS 6 14 TROUBLESHOOTING This page is intentionally left blank ...
Страница 102: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 106: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...