TROUBLESHOOTING
Causes
Checking
Comments
Actions
Equipment power
supply malfunction.
Check voltage between phases
and neutrals in the main terminal.
Check voltage in CN4 connector
(power board).
Voltages will vary depending on
power supply.
Check wiring.
Check net power
supply. Change
electric supply cable.
Melter thermostat
malfunction.
Check continuity in thermostat
(2S2.1).
If continuity, switch is OK. Reset
it.
Change thermostat.
Switch malfunction.
Check continuity in switch (1S2)
If continuity in CN7 connector,
switch is OK.
Change switch.
Power board
malfunction.
Check voltage in CN8 connector.
Bypass CN8 pins. If 230V, the
board is correct.
Change power board.
Control board fuse
damaged.
Verify continuity in fuse (F1).
Check first 230V is supplied to
the control board (CN8)
Change fuse.
Control board
malfunction.
Check voltage in CN9 connector.
Fuse works and 230V arrive to
control board
Change control board.
Melter
The unit does not turn on (5, 10 and 20 adhesive melters)
Causes
Checking
Comments
Actions
Equipment power
supply malfunction.
Check voltage between phases
and neutrals in the main terminal.
Check voltage in CN4 connector
(power board).
Voltages will vary depending on
power supply.
Check wiring.
Check net power
supply. Change
electric supply cable.
Melter thermostat
malfunction.
Check continuity in thermostat
(*)
.
( 1 )
If continuity, switch is OK. Reset
it.
Change thermostat.
Switch malfunction.
Check continuity in switch (1S2)
If continuity in CN7 connector,
switch is OK.
Change switch.
Faulty contactor.
Check that the contactor (*)
( 2 )
receives 230 V (A1-A2) and then
check for continuity between the
contacts (13-14).
The contactor is working
properly if it receives 230 V and
there is continuity between
contacts 13-14.
Replace the contactor.
Power board
malfunction.
Check voltage in CN8 connector.
Bypass CN8 pins. If 230V, the
board is correct.
Change power board.
Control board fuse
damaged.
Verify continuity in fuse (F1).
Check first 230V is supplied to
the control board (CN8)
Change fuse.
Control board
malfunction.
Check voltage in CN9 connector.
Fuse works and 230V arrive to
control board
Change control board.
Note
Micron, 1 geared motor
Micron, 2 geared motors
(1)
7S4
9S4
(2)
7K3
9K3
The unit does not turn on (35 adhesive melter)
Содержание Micron 5
Страница 1: ...ADHESIVE MELTER MICRON GEAR SERIES INSTRUCTIONS MANUAL MA 5079 ENG 200718 GLUING SOLUTIONS ...
Страница 10: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 36: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Страница 70: ...FOCKE MELER GLUING SOLUTIONS 4 34 MELTER OPERATION This page is intentionally left blank ...
Страница 80: ...FOCKE MELER GLUING SOLUTIONS 5 10 MAINTENANCE This page is intentionally left blank ...
Страница 94: ...FOCKE MELER GLUING SOLUTIONS 6 14 TROUBLESHOOTING This page is intentionally left blank ...
Страница 102: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 106: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...