- 25 -
2CD-7713v1/GDB5F40
Instructions Manual
4-2. Connection of AL-
communication system
Ⅱ
Operation not anticipated may cause damage of the machine and the product.
To prevent the malfunction by the noise, the AL-
communications cable recommends
QAUTION
Ⅱ
recommended cable.
1
Core connection of AL-
communications cable
( )
Ⅱ
Please install the core in the master side. And, the personal computer system including the AL -
communication
Ⅱ
is made to operated with stability.
The core is prepared by our company.
Please refer to the "connection/other" manual.
2 Connection of terminator
( )
Please connect terminator CB-54/R
with the slave unit arranged on the AL-
communication network edge.
(
)
Ⅱ
Please do not connect the terminator with other equipment.
There is no problem even if AL-
communications or the terminator are connected with either of J1, J2.
Ⅱ
AL-
communication network
Terminator
Core
Ⅱ
CB-54/R
AL2-01v1/PCI
2C-776Av1
2CD-7713v1/
2CD-7713v1/
Master
etc.
GDB5F40 etc.
GDB5F40 etc.
(
)
Terminator
Terminator
Terminator
Terminator
Always on Inside
Unconnection
Unconnection
Connection
(
)
3
Wiring distance of AL-
communication
( )
Ⅱ
The total wiring distance of the AL-
communications cable is the following range including the multidrop wiring.
Ⅱ
The wiring distance of Extend I/O doesn't relate to AL-
communication baud rate RATE .
・
Ⅱ
(
)
The wiring distance of Extend I/O from each slave is within 1 m.
・
L1 / RATE
(
)
Multi drop
Terminator Build-in
Terminator
(
)
Address
Address
Address
Slave unit
Address
Address
(
)
=0
=1
=2
=14
=15
L2
(
)
Master
(
)
(
)
(
)
(
)
Extend I/O
Extend I/O
Extend I/O
Extend I/O
AL-
communication baud rate and wiring distance
●
Ⅱ
RATE
Wiring distance
10 Mbps
20 Mbps
L1 AL-
communication
100 m or less
50 m or less
(
Ⅱ
)
L2 Extend I/O communication
1 m or less
(
)
The number of slaves that can be connected directly with the AL-
communication are 15 units or less.
●
Ⅱ
Extend I/O that can be extended directly from the slave unit is not included in the number of slaves.
4
Power supply and slave power supply for communication
( )
The AL-
communication power supply of each slave unit is supplied from the AL-
master through the
Ⅱ
Ⅱ
communications cable so that the entire AL-
communication network should not become unstable when the
Ⅱ
power supply on each slave unit side is intercepted.
The reconnection of communications can be done by executing Environment-function to the master when the power
supply of the main unit on the slave side is obstructed.
Moreover, 2CD-7713v1/GDB5F40 can independently intercept driving power supply with the controller power supply
maintained for the safety of the equipment.
Master side
(Personal computer side)
Core:ZCAT2032-0930
The core is fixed with INSULOK.
Installs it within 40mm.