- 23 -
2CD-7713v1/GDB5F40
Instructions Manual
5
Setting of HOLD CURRENT SELECT HOLD I. SEL
switch
( )
(
)
Erroneous setting may cause burn on the skin due to overheating of the motor.
Do not select a high value beyond the required.
QAUTION
HOLD current is set up with the HOLD I. SEL switch.
The ratio of the HOLD current to the DRIVE current is set.
It is set
No. 3: 40 %
in factory-set.
〔
〕
HOLD current
Ratio of HOLD current
100
(%)=
×
DRIVE current
〔
〜
〕
〔
〜
〕
DRIVE I. SEL
No. 0
No. 2
DRIVE I. SEL
No. 3
No. F
(%)
(%)
HOLD I. SEL No.
HOLD I. SEL No.
Ratio of HOLD current
Ratio of HOLD current
0
0
10
−
1
20
1
20
2
30
2
30
3
40
3
40
Factory-set
←
4
50
4
50
5
60
5
60
6
70
6
70
7
80
7
80
8
90
8
90
9
100
9
100
HOLD current is changed relative to DRIVE current setting.
・
The ratio of HOLD current of 100% No. 9 setting
represents the same as the setting for DRIVE current.
(
)
When the DRIVE I. SEL switch is set to No. 0
No. 2, the useful range of the HOLD I. SEL switch
・
〜
becomes No. 1
No. 9.
〜
No.0 becomes the range of 0
20 %.
〜
The greater the ratio of HOLD current grows, the more heat the motor generates when on holding-state.
・