TOUCH CONTACT PAD TEST
Conditions for the voltage measurements
Fail conditions
UK and EU 230 V
IF ((LE <= 0.9*230 V) and (NE >= 0.1*230 V)) OR ((LE >= 0.1*230 V) and (NE <= 0.9*230 V))
US 120 V 1Ph
IF ((LE <= 0.9*120 V) and (NE >= 0.1*120 V))
US 208 V 2Ph
IF (LE - NE >= 10 V)
US 240 V 2Ph
IF (LE - NE >= 10 V)
Pass conditions
UK and EU 230 V
IF ((LE >= 0.9*230 V) and (LE <= 1.1*230 V) and (NE <= 0.1*230 V))
Reversed EU
IF ((LE <= 0.1*230 V) and (NE >= 0.9*230 V) and (NE <= 1.1*230 V))
US 120 V 1Ph
IF ((LE >= 0.9*120 V) and (LE <= 1.1*120 V) and (NE <= 0.1*120 V))
US 208 V 2Ph
IF ((LN >= 0.9*208 V) and (N <= 1.1*208 V) and (LE - NE <,= 10 V))
US 240 V 2Ph
IF ((LN >= 0.9*240 V) and (LN <= 1.1*240 V) and (LE - NE <= 10 V))
Dangerous voltage indication at PE conductor
POWER SUPPLY
Battery:
Four AA cells Alkaline ONLY
CONNECTIONS
Type 2 male – main test connection
4 mm shrouded socket on base of handle – RPE test return connection
LANGUAGES
User interface:
English, French, German, Dutch and Spanish
User guide:
English, French, German, Dutch and Spanish
DIMENSIONS AND WEIGHTS
Dimensions (L x H x W)
24 x 18 x 8.6 cm
Weight (without batteries)
583 g
SAFETY
Standards
IEC 61010-1:2010
Safety category
CATII 300 V
EVSE standard
IEC 61851-1:2017
ENVIRONMENT
Operational temperature
0 ºC to 40 ºC
Storage temperature
-10 ºC to 70 ºC
Operating humidity
90% R.H. at +40 °C max
Maximum altitude:
2000 m
Dust and moisture ingress:
IP40 to IEC60529 in use
42
Specifications
www.calcert.com
1.800.544.2843
0
5
10
15
20
25
30