background image

www.megger.com

DLRO10 and DLRO10X

22

10.  ACCESSORIES

Standard Accessories supplied with all instrument.

Battery DLRO10/10X 5.2 Ah

6121-492

User guide DLRO10/10X

6172-681

Warranty / Cert of Test [1 YEAR] MEGGER

2000-231

Test leads supplied with instruments

DLRO10-NLS Ducter Ohmmeter NO LEAD SET

1006-660

DLRO10X-NLS Ducter Ohmmeter NO LEAD SET

1006-659

DLRO10 Ducter Oh DH4-C

1006-598

DLRO10X Ducter Oh DH4-C

1006-600 

DH4-C Connect Duplex Handspike 1.5m (x2)

1006-444

Optional Accessories at extra cost

Carrying Case for DLRO10/10X + all accessories 

6380-138

Calibration Shunt , 10 Ω, current rating 1 mA

249000

Calibration Shunt resistor, 1 Ω, current rating 10 mA

249001 

Calibration Shunt resistor, 100 mΩ, current rating 1A

249002 

Calibration Shunt resistor, 10 mΩ, current rating 10 A

249003

Calibration certificate

CERT-NIST

Replacement tips for DH4 handspikes. 

Needle point

1008-024

Waffle end

1010-929

DLRO10LPU-EU Mains Line Power Unit - SCHUKO plug

1003-172

DLRO10LPU-UK Mains Line Power Unit - UK plug

1003-093

DLRO10LPU-US Mains Line Power Unit - US plug

1003-171

DLRO10LPU line power unit

The DLRO10 and DLRO10X may be also powered from an optional 
mains / line power supply unit the DLRO10LPU. This unit is simply fitted 
to the instrument in place of the standard battery pack. 
When in use a red LED is illuminated when the instrument is powered 
from a mains / line power supply. The DLRO10X is seen here fitted with 
the optional DLRO10LPU. Ideal for repetitive testing applications such as 
manufacturing production line use

Optional Test Leads at extra cost Duplex Leads Normal test 
leads not fitted with inline connector:

DH4-C Connect Duplex Handspike 1.5m (x2)

1006-444

DH5 straight duplex handspikes (2). One has indicator lights.

2.5 m/8 ft

6111-517

DH6 Duplex handspikes (2) suitable for working on 600 V. systems.

2.5 m/8 ft

6111-518

Duplex Handspikes (2)with spring loaded helical contacts.

2 m/7 ft 

242011-7

2.5 m/8 ft 

6111-022

5.5 m/18 ft 

242011-18

6 m/20 ft 

6111-023

9 m/30 ft

6111-024

Straight Duplex Handspikes (2) Heavy Duty with fixed contacts.

2 m/7 ft 

242002-7

5.5 m/18 ft 

242002-18

9 m/30 ft 

242002-30

Содержание DLRO-10

Страница 1: ...DLRO10 and DLRO 10X Digital Low Resistance Ohmmeter User Guide User Guide DLRO10 and DLRO10X Digital Low Resistance Ohmmeter...

Страница 2: ...ltage Warning 8 4 4 Discharge Current Warning 8 4 5 The Menu 8 4 6 Test Menu 9 4 7 Options Menu 9 4 7 1 Retrieve 9 4 7 2 Download 10 4 8 Passbands 10 4 9 Set Clock 11 4 10 Delete Data 11 4 11 Storage...

Страница 3: ...8 7 3 1 Standard Charging 18 7 3 2 WARNING 18 8 SPECIFICATIONS 19 9 TROUBLE SHOOTING 21 10 ACCESSORIES 22 11 REPAIR AND WARRANTY 24 11 1 Instrument Repair and Spare Parts 24 11 2 Approved Repair Compa...

Страница 4: ...to achieve this For testing large inductive resistances the current carrying leads should be connected securely to the item under test before starting the test It is not recommended that duplex handsp...

Страница 5: ...ectrical outlets CAT IV Measurement category IV Equipment connected between the origin of the low voltage mains supply and the distribution panel 1 1 Symbols used on the instrument G Caution Refer to...

Страница 6: ...at the back and held closed by magnetic catches covers the top panel This lid may be removed if required by opening fully and snapping out of its hinges Both instruments are protected against accident...

Страница 7: ...he lamp will not operate if the instrument is turned off The I lamp will light if a current greater than 1 mA is still flowing after a test is completed This suggests that an inductive load has been t...

Страница 8: ...measurement cannot be made if any of these messages is visible on the display 4 3 3 External Voltage Warning If external voltage is applied to the terminals a message EXT VOLTS will flash on the displ...

Страница 9: ...mode 4 7 Options Menu The Options menu has five options that are not related to each other as shown below There is a quick access menu that can be accessed using the numbers keys as follows 0 Retriev...

Страница 10: ...on allows you to set upper and lower limits between which the test result average must fall if it is to be signalled as a Pass GREEN Readings outside these limits will be signalled as a Fail RED Set t...

Страница 11: ...o clear DLRO10X s memory of stored data In case you have selected this Option by accident you will be asked to confirm that you wish to delete the data the default is NO Change this to YES and press E...

Страница 12: ...is automatically limited to 1A When Battery level is low 10 the maximum test current is automatically reduced by one level and will be further reduced when a test has to be abandoned because the batt...

Страница 13: ...he test number to 1 4 15 Keypad Operation The 12 key keypad is similar to those used on mobile telephones in that each key is capable of producing one of several characters depending on the number of...

Страница 14: ...ts on loads that exhibit an inductive component using the test mode indicated by the inductor symbol on the DLRO10 or by using the inductive mode on the DLRO10X When measuring inductive loads it is es...

Страница 15: ...as shown in the next section Testing Using Duplex Handspikes or Individual Leads One of the DH4 handspikes is fitted with two lamps marked L1 and L2 and an extra lead This lead should be plugged into...

Страница 16: ...two measurements Both measurements are displayed by DLRO 10X along with the average while the DLRO 10 displays the average only If the combined resistance of the current leads and test sample is grea...

Страница 17: ...e retaining clips and pull the top of the clip away from the instrument body The module now unplugs from the base of the instrument Plug in the charger or connect to a 12 volt vehicle type battery usi...

Страница 18: ...Charging The battery module is charging at its standard rate Fast Battery state flashing during charging indicates temperature fault 7 3 2 WARNING Connecting to greater than 15 volts can cause perman...

Страница 19: ...e and Safety LED Indication Measurement Mode Manual Auto Continuous Inductive Manual Auto Continuous Inductive Unidirectional Control Fully Automatic Fully Automatic with manual override of maximum cu...

Страница 20: ...to 122 F at reduced accuracy Storage 30 C to 70 C 22 F to 158 F Calibration 20 C 68 F Coefficient 0 01 per C from 5 C to 40 C 0 006 per F from 41 F to 104 F Standard charging 0 C to 40 C 32 F to 104...

Страница 21: ...RR 114 Checksum Failure in EEPROM Calibration constants have been lost The DLRO will continue to work but the accuracy can now not be guaranteed At switch on the display will show the software version...

Страница 22: ...3 172 DLRO10LPU UK Mains Line Power Unit UK plug 1003 093 DLRO10LPU US Mains Line Power Unit US plug 1003 171 DLRO10LPU line power unit The DLRO10 and DLRO10X may be also powered from an optional main...

Страница 23: ...06 18 9 m 30 ft 242006 30 Single Leads Single handspikes 2 for potential measurement 2 m 7 ft 242021 7 5 5 m 18 ft 242021 18 9 m 30 ft 242021 30 Current clips 2 for current connections 2 m 7 ft 242041...

Страница 24: ...r Repair If returning an instrument to the manufacturer for repair it should be sent freight pre paid to the appropriate address A copy of the Invoice and of the packing note should be sent simultaneo...

Страница 25: ...cell is located behind the display Dispose of in accordance with local regulations The lithium ion is classified as an industrial battery For disposal in the UK contact Megger Ltd For disposal of batt...

Страница 26: ...USA T 800 723 2861 USA only T 1 214 333 3201 F 1 214 331 7399 E USsales megger com Megger AB Rinkebyv gen 19 Box 724 SE 182 17 DANDERYD T 46 08 510 195 00 E seinfo megger com Megger USA Fort Collins...

Отзывы: