background image

 

D

0125127

C

       

  

 

39

 

Technical

 

Information

 

The

 

Avant

 

REM+

 

is

 

an

 

active,

 

diagnostic

 

Class

 

IIa

 

Medical

 

Device

 

according

 

to

 

the

 

EU

 

Medical

 

Device

 

Regulation

 

2017/745.

 

 

Standards:

 

 

IEC

 

60601

1:2

 

Class

 

II

 

IEC

 

60601

1

2

 

Class

 

A

 

IEC

 

60645

1

 

Medical

 

Device

 

Regulation

 

2017/745

 

 

REM

 

 

Standards:

 

ANSI

 

S3.46,

 

IEC

 

61669,

 

EN

 

61669

 

Dimensions:

 

Approx.

 

16

 

cm

 

x

 

12

 

cm

 

x

 

3

 

cm

 

(L

 

x

 

W

 

x

 

H)

 

Approx.

 

6.5

″ 

x

 

5

″ 

x

 

1.25

″ 

(L

 

x

 

W

 

x

 

H).

 

Weight:

 

<

 

500

 

g

 

<

 

1

 

lb

 

System

 

Modality:

 

Real

 

Ear

 

Measurement;

 

Binaural

 

Live

 

Speech

 

Mapping;

 

Hearing

 

Loss

 

Simulator;

 

Hearing

 

Instrument

 

Simulator.

 

Probe

 

Microphones

 

(L/R):

 

Dual

 

Electret

 

Microphone

 

Elements

 

(2

 

Probe

 

Microphones)

 

Probe

 

Microphone

 

Tube:

 

Silicone

 

1.0

 

mm

 

Nominal

 

Diameter

 

Measurement

 

Frequency

 

Range:

 

125

 

 

8000

 

Hz

 

Test

 

Stimuli:

 

Broadband

 

Noise

 

and

 

Synthesized

 

Random

 

Noise

 

 

Pink,

 

White,

 

Byrne

 

LTASS

 

and

 

ANSI

 

weighted;

 

ICRA;

 

ISTS;

 

Microphone,

 

File,

 

CD

ROM

 

for

 

Live

 

Speech

 

Mapping,

 

Chirp

 

Test

 

Stimulus

 

Levels

 

at

 

1m

:

 

45

 

 

90

 

dB

 

SPL

 

in

 

1

 

dB

 

Steps

 

 

200

 

Hz

 

thru

 

8K

 

Hz

 

(depending

 

on

 

speaker

 

wattage

 

&

 

efficiency)

 

Test

 

Stimulus

 

Accuracy:

 

±

 

3

 

dB

 

SPL

 

Analysis

 

Mode:

 

User

 

Selectable

 

1/3,

 

1/6,

 

1/12,

 

1/24,

 

1/48

 

Octave

 

Bands

 

ANSI

 

S3.46

 

Test

 

Available

 

IEC/EN

 

61669:

 

Real

 

Ear

 

Unaided

 

Response,

 

Real

 

Ear

 

Unaided

 

Gain;

 

Real

 

Ear

 

Insertion

 

Gain;

 

Real

 

Ear

 

Occluded

 

Response;

 

Real

 

Ear

 

Occluded

 

Gain;

 

Real

 

Ear

 

Aided

 

Response;

 

Real

 

Ear

 

Aided

 

Gain

 

Other

 

Test

 

Available:

 

Live

 

Speech

 

Mapping

 

with

 

Peaks

 

and

 

LTASS

 

analysis;

 

Real

 

Ear

 

to

 

Coupler

 

Difference,

 

Occlusion

 

Effect,

 

Percentile

 

Analysis

 

Prescription

 

Methods:

 

NAL

RP;

 

1/3

 

Gain;

 

1/2

 

Gain;

 

Berger;

 

Pogo

 

1;

 

Pogo

 

2;

 

FIG6;

 

DSL

 

m[I/O]

 

NAL

NL1;

 

NAL

NL2

 

External

 

Connections:

 

Power

 

Connection

 

USB

 

2.0

 

Input

 

5.0

 

Volt

 

Bus;

 

Line

Output

 

Jack

 

(Speakers)

 

3.5

 

mm

 

Stereo

 

Jack;

 

Speaker

 

Output

 

(Internal

 

Amplifier)

 

(2)

 

3.81mm

 

Pluggable

 

Spring

 

Clamp;

 

Probe

 

Microphones

 

Inputs

 

(2)

 

8

 

Pin

 

Mini

DIN;

 

Operator

 

Headset

 

Jack

 

3.5

 

mm

 

Stereo

 

Jack;

 

Patient

 

Headset

 

Jack

 

3.5

 

mm

 

Stereo

 

Jack;

 

Power

 

Jack

 

2.1

 

mm

  

X

 

5.5

 

mm.

 

Communication:

 

Talk

 

forward

 

and

 

talk

 

back

 

Data

 

Connection:

 

USB

 

Mode

 

of

 

Operation:

 

Continuous

 

Warm

 

up

 

Time:

 

Less

 

than

 

5

 

min

 

after

 

USB

 

connection

 

Weight:

 

<

 

900

 

g

 

<

 

2

 

lb

 

Power

 

Supply:

  

100

 ‐ 

240

 

V~

 

50/60

 

Hz

 

±10

 

%

 

producing

 

15

 

VDC

  

USB:

 

5

 

VDC

 

Power

 

Consumption:

  

Less

 

than

 

500

 

mA

 

at

 

15

 

VDC

 

/

 

less

 

than

 

500

  

mA

 

at

 

5

 

VDC

 

Connection

 

Sockets:

 

Specification

 

Power/Communication

 

USB:

 

(5

 

VDC)

 

Power

 

15

 

VDC

 

Speaker

 

left

 

ZA=

 

4

,

 

UA=

 

8

 

Veff

 

Speaker

 

right

 

ZA=

 

4

 Ω

,

 

UA=

 

8

 

Veff

 

Operator

 

Monitor

 

headphone

 

ZA=

 

32

Ω 

,

 

UA=

 

3

 

Veff

 

Left

 

Probe

  

ZI=

 

1

 

k

 Ω

,

 

UI=

 

0.38

 

 

500

 

mVeff

 

Right

 

Probe

  

ZI=

 

1

 

k

 Ω

,

 

UI=

 

0.38

 

 

500

 

mVeff

 

Patient

 

(Client)

 

headphone

 

ZA=

 

32

Ω 

,

 

UA=

 

3

 

Veff

 

Line

 

Level

 

Stereo

 

Speaker

 

Output

 

ZA=

 

32

Ω 

,

 

UA=

 

3

 

Veff

 

Содержание Avant REM+

Страница 1: ...D 0125127 C 1...

Страница 2: ...d 105 Largo FL 33771 U S A Toll Free 888 392 1234 727 584 9600 Fax 727 584 9602 Email medrx medrx diagnostics com MedRx s Authorized Representative in Europe DGS Diagnostics A S Audiometer Alle 1 5500...

Страница 3: ...ep Guide to Live Speech Mapping 16 Speech Mapping with Recorded Inputs 17 Speech Mapping with Live Voice Inputs 18 Running Speech Mapping On Top 19 MedRx Live Speech Mapping Protocol 19 Real Ear Measu...

Страница 4: ...ect Help Topics Select an item from the list in the Index tab and click Display Measurement uncertainty is 1 dB Getting to Know Your AVANT REM Intended Use Statement The hearing aid analyzer is intend...

Страница 5: ...with your REM device Use of unapproved accessories is not recommended Probe Microphones Probe Mic Hanger Headphones Optional DC Power Supply Optional Bluetooth Active Speaker Bluetooth Speaker Audio...

Страница 6: ...h the Red Blue connectors Place a small flat head screw driver on the small orange tabs and push down while inserting a speaker wire into the opening then remove the screw driver Be sure the wire is s...

Страница 7: ...ll the hook on the back side of the probe mic Pull hook down to seat on the post 3 Once installed the large O rings should be adjustable for fitting 4 Gently press clip into place 5 Turn clip over pla...

Страница 8: ...placed at a distance of about 1 meter 19 39 from the patient for normal use It is preferred to plug the speaker into the power supply but it may be powered by the internal battery The Bluetooth option...

Страница 9: ...Studio shortcut on your Windows Desktop Noah Launch Noah Select a patient Launch MedRx Studio module following Noah procedures Basic Software Options Several options are available which allow the user...

Страница 10: ...op right corner of the software or pressing the F1 key Live Speech Mapping Select LSM from the main menu Top Tool Bar The Tool Bar icons have the following functions 1 On Top Window 2 Tube Calibration...

Страница 11: ...Ear Selection 2 Stimulus Selection 3 Viewing Mode 4 Open Fit Function 5 Start Stop Buttons The Target Selection icon sets up 1 Target type 2 Client information 3 Hearing aid parameters The Display ico...

Страница 12: ...ets your default view and default target levels The General tab defines the default appearance of the Live Speech Mapping test environment The Fitting tab sets the default fitting rule client informat...

Страница 13: ...tab sets the tests displayed in the Live Speech Mapping module The REUR tab sets the default appearance and units displayed on the REUR graph The REOR tab sets the default appearance and units display...

Страница 14: ...positioned in such a way that nothing blocks the path of the emanated sound in front and on the sides of the speaker For example positioning a speaker behind a monitor is incorrect and can severely af...

Страница 15: ...be at least 70 dB to complete a valid calibration If the screen prompt indicates the signal is too low increase the volume on the loudspeaker or move the patient closer and restart the calibration Re...

Страница 16: ...ed you may manually enter the audiometric data into the REM software as follows 1 Under General then Shown Tests select show Tone 2 Select AUD module located at the top left of the software 3 Using yo...

Страница 17: ...suring A pure tone or white noise will be presented and once it reaches the selected input level with the slide bar the chosen track will play When enough data is collected click the Stop button to st...

Страница 18: ...ing MedRx Modified Speech Spectrum DSL IO NAL NL2 NAL NL1 Speech Mapping with Live Voice Inputs Using the microphone allows measurement of both the professional s voice and that of a third party e g t...

Страница 19: ...full control over the measurement environment firmly in the hands of the hearing care professional The system is powerful yet extremely flexible allowing each provider to use Live Speech Mapping in a...

Страница 20: ...solution 7 Carefully place the hearing instrument in the ear without disturbing the probe tube 8 Complete a Live Speech Mapping measurement AIDED LSM 9 Using the On Top mode make any adjustments neede...

Страница 21: ...e Help files under the topic Signal Types Access these by clicking on the Help tab at the top of the screen and selection Help Topics Select an item from the list in the Index tab and click Display Me...

Страница 22: ...of the window Stimulus Signal Types Pure Tone A pure sine wave Crest Factor 1 41 3 0dB Broadband Noise BBN Uniform random noise with normal Gaussian amplitude distribution Can be weighted to White Pi...

Страница 23: ...as steep as Byrne weighted so there is more power in higher octaves This will result in less gain required by the hearing aid to reach targets but may result in under fitting at high frequencies Cres...

Страница 24: ...rel or feel blocked up These are signs of a build up of self generated low frequency energy in the ear canal This excessive occlusion can be measured objectively in the Occlusion Effect task The Real...

Страница 25: ...rn the compression and noise reduction circuits off Using open fit hearing aids for RECD measurements may result in invalid low and mid frequency measurements because of insufficient gain at those fre...

Страница 26: ...In this case to obtain another RECD only REAR with insert headphone measurement is necessary This is possible because the coupler response does not change provided that neither the coupler nor the in...

Страница 27: ...l hearing person would perceive the sound Toggle between these selections as necessary 5 The Reset option restores the audiogram to the original state Use this option if you have modified the audiogra...

Страница 28: ...ayer panel to control the playback CD allows the user to play music CDs After the option is activated use the player panel to control the playback How to use the Master Hearing Aid 1 Select the Master...

Страница 29: ...late with the pencil icon Editing a template will open the print editor and allow you to adjust print elements 8 Duplicate existing templates icon 9 Delete template icon To Use an Existing Print Templ...

Страница 30: ...8 Drag and drop elements onto the page to create your template a You can combine data from multiple modules into a single template b Elements may overlap and will stack cover previously added elements...

Страница 31: ...to many beautiful colors These take the shape of a long round arch with its path high above and its two ends apparently beyond the horizon There is according to legend a boiling pot of gold at one end...

Страница 32: ...exception of transducers and cables sold by the manufacturer of the Avant REM as replacement parts for internal components may result in increased emissions or decreased immunity of the Avant REM The...

Страница 33: ...Non applicable Guidance and manufacturer s declaration electromagnetic immunity The Avant REM is intended for use in electromagnetic environment specific below The customer or the user of the Avant R...

Страница 34: ...ers m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vici...

Страница 35: ...s 150 kHz to 80 MHz d 1 17 P 80 MHz to 800 MHz d 1 17 P 800 MHz to 2 5 GHz d 2 33 P 0 01 0 12 0 12 0 233 0 1 0 37 0 37 0 74 1 1 17 1 17 2 33 10 3 7 3 7 7 40 100 11 7 11 7 23 3 For transmitters rated a...

Страница 36: ...C to 50 C and humidity level from 10 to 90 All components with patient contact are made of bio compatible materials This device does not produce any adverse physiological effects Install the device a...

Страница 37: ...MedRx Authorized Representative in Europe Non ionizing electromagnetic radiation Special Disposal Required Humidity Limitation Caution General warning sign Temperature limitation Read the instruction...

Страница 38: ...n cloth or sealed Alcohol swabs for each device to be cleaned 4 Wipe the surfaces of the probe microphone black ear loop and headphone pads with the 70 Isopropyl Alcohol Clean other transducers in the...

Страница 39: ...Real Ear Unaided Gain Real Ear Insertion Gain Real Ear Occluded Response Real Ear Occluded Gain Real Ear Aided Response Real Ear Aided Gain Other Test Available Live Speech Mapping with Peaks and LTAS...

Страница 40: ...of the purchaser MedRx shall not be liable for any consequential or incidental damages or for breach of any express or implied warranty Except to the extent of applicable law any implied warranty merc...

Отзывы: