4

 

 

GENERAL DESCRIPTION 

Pump and Mattress 

 

Controls and Features 

 

 
 

 

 

 

 

 

 

 

 

Main Control Panel

 

   

 POWER SWITCH                                     

 

 CYCLE TIME

 

       

When LED is illuminated the power is on. 

                

Adjust the cycle time from 10,15, 20 and 

                                                                                                      

25 minutes for “Alternating” cell function. 

 

   

 

 THERAPY/AUTO FIRM

 

         

a. AUTOFIRM: Quickly inflates mattress to maximum firmness. 

     b. ALTERNATING: Normal alternating function 
     c. STATIC: Does not alternate & keeps mattress firm and always inflated 

  d. SEAT FUNCTION: To increase pressure in each cell when mattress is in the sitting position.

 

 

   

 COMFORT                                                         

 LOW PRESSURE

 

         

To increase or decrease airflow for a softer                

Low Pressure light will illuminate and alarm sounds   

          or firmer setting between 1 to 10 range. 

                   

when the pressure is below the preset level. Reset system.               

 
 

   

 POWER FAILURE                                             

 PANEL LOCK

 

         

Mutes the audible alarm when LED turns off. 

           

   

Locks all functions* automatically after 5 mins.   

                                                                                                            To disable, press and hold the button for 3 sec.   

   

   

 

 

 

 

 

 

 

 

 

      *

 Except “Power”, “Low Pressure” and “Alarm Off” function. 

 

               
 

 

 

 

 

 

Содержание Comfort Zone CZ36

Страница 1: ...User Manual FOR MODEL CZ36 CZ36 BIP 8 REPLACEMENT CELL ON CELL MATTRESS 2016 MADE IN CHINA...

Страница 2: ...ORE USE page 6 USE WARNINGS page 6 7 HOW TO USE page 7 HOW TO USE THE CPR DEFLATOR INFLATOR page 7 8 STORAGE page 9 MAINTENANCE page 9 CLEANING AND DISINFECTION page 9 CONDITIONS OF DISPOSAL page 9 Ge...

Страница 3: ...ct for any purpose not indicated in this manual Only qualified personnel trained in the treatment and prevention of bedsores should operate this device MedaCure Inc declines all liability for any cons...

Страница 4: ...nt otherwise injury or damage may occur 2 Consult with physician or therapist to determine the correct adjustment and the correct use of this device 3 Keep the packed kit away from heat sources 4 SERV...

Страница 5: ...ernate keeps mattress firm and always inflated d SEAT FUNCTION To increase pressure in each cell when mattress is in the sitting position COMFORT LOW PRESSURE To increase or decrease airflow for a sof...

Страница 6: ...r 5 Fuse Back 8 Filter 9 Main filter 10 Protective cap of filter 11 Hook 1 Pillow 2 Cover 3 Fixing belt 4 Low air loss holes 5 Male quick connector 6 Protective cap of connector 7 Air tubing 8 Patente...

Страница 7: ...e of a sudden power outage The mattress will temporarily retain air even when the pump is turned off or during a power outage Please note this only temporary The cover sheet protects the cells against...

Страница 8: ...plug the control unit into the ground power supply 7 Do not use the product in case of the following 1 the plug or the cable is damaged 2 the system sounds abnormal or vibrates intensely 3 the control...

Страница 9: ...ng 4 Align the air holes as shown to deflate 1 This mattress includes a Quick Inflate Pump and nozzle attachment 2 Attach the nozzle to the pump as shown 3 Align the air holes on the CPR Insert the Qu...

Страница 10: ...t by bringing it to a specific recycling point for electric and electronic equipment or others that provide this service SPARE PARTS ACCESSORIES For spare parts and accessories please contact MedaCure...

Страница 11: ...emissions CISPR 11 Group 1 The device uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment...

Страница 12: ...to line s 2kV line s to earth 1kV differential mode 2kV differential d Mains power quality should be that of a typical commercial or hospital environment Voltage Dips short interruptions and voltage...

Страница 13: ...ngths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment...

Страница 14: ...ower of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73...

Страница 15: ...peration 10 40 Storage 15 50 Shipping 15 70 Environment humidity Operation 10 90 non condensing Storage 10 90 non condensing Shipping 10 90 non condensing Atmospheric Pressure Operation 700 1013 25hPa...

Страница 16: ...alling Patient must be under the constant watch of a caregiver to monitor the patient s movements When the patient needs to transfer out of bed each side can be deflated individually to allow the pati...

Отзывы: