STANDARDS 

The system has been tested and successfully approved to the following standards: 
EN 60601-1 
EN 60601-1-1-2 

GENERAL WARNINGS

   

Keep this manual in a safe place and refer to the manual before use and  under proper medical 
supervision. Improper operation of this system may cause damage t o  the product and possible injury to the 
user.

 

1. Do not use this product or any available optional equipment without first completely reading and

understanding this instruction manual. If you are unable to understand the warnings, cautions or
instructions, please contact a healthcare professional, dealer or authorized technician before attempting
to use this equipment, otherwise injury or damage may occur.

2. Consult with physician or therapist to determine the correct adjustment and the correct use of this device.
3. Keep the packed kit away from heat sources.
4. SERVICE LIFE-the device use limit is defined by the wear of the parts.
5. Do not allow children to play with or operate the pump or mattress.

SYMBOLS 

     

Caution     

        Do not bleach 

    Medical Devices Directive 93/42/EEC         

      Tumble dry with low heat 

    Electrical Protection Type B           

      The marking of electrical and electronics   

          devices according to Directive 2002/96/EC. 
          The device, accessories and the packaging 

 Class II Equipment (Double Insulated)     

  must be disposed of correctly at  

          the end of the usage. 
          Please follow local ordinances or 
          regulations for disposal. 

    Do not iron           

  Date of manufacture   

  Compatible with any dry cleaning method      

        No more than 80 degree wash   

    Refer to manual before use     

Содержание Comfort Zone CZ36

Страница 1: ...User Manual FOR MODEL CZ36 CZ36 BIP 8 REPLACEMENT CELL ON CELL MATTRESS 2016 MADE IN CHINA...

Страница 2: ...ORE USE page 6 USE WARNINGS page 6 7 HOW TO USE page 7 HOW TO USE THE CPR DEFLATOR INFLATOR page 7 8 STORAGE page 9 MAINTENANCE page 9 CLEANING AND DISINFECTION page 9 CONDITIONS OF DISPOSAL page 9 Ge...

Страница 3: ...ct for any purpose not indicated in this manual Only qualified personnel trained in the treatment and prevention of bedsores should operate this device MedaCure Inc declines all liability for any cons...

Страница 4: ...nt otherwise injury or damage may occur 2 Consult with physician or therapist to determine the correct adjustment and the correct use of this device 3 Keep the packed kit away from heat sources 4 SERV...

Страница 5: ...ernate keeps mattress firm and always inflated d SEAT FUNCTION To increase pressure in each cell when mattress is in the sitting position COMFORT LOW PRESSURE To increase or decrease airflow for a sof...

Страница 6: ...r 5 Fuse Back 8 Filter 9 Main filter 10 Protective cap of filter 11 Hook 1 Pillow 2 Cover 3 Fixing belt 4 Low air loss holes 5 Male quick connector 6 Protective cap of connector 7 Air tubing 8 Patente...

Страница 7: ...e of a sudden power outage The mattress will temporarily retain air even when the pump is turned off or during a power outage Please note this only temporary The cover sheet protects the cells against...

Страница 8: ...plug the control unit into the ground power supply 7 Do not use the product in case of the following 1 the plug or the cable is damaged 2 the system sounds abnormal or vibrates intensely 3 the control...

Страница 9: ...ng 4 Align the air holes as shown to deflate 1 This mattress includes a Quick Inflate Pump and nozzle attachment 2 Attach the nozzle to the pump as shown 3 Align the air holes on the CPR Insert the Qu...

Страница 10: ...t by bringing it to a specific recycling point for electric and electronic equipment or others that provide this service SPARE PARTS ACCESSORIES For spare parts and accessories please contact MedaCure...

Страница 11: ...emissions CISPR 11 Group 1 The device uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment...

Страница 12: ...to line s 2kV line s to earth 1kV differential mode 2kV differential d Mains power quality should be that of a typical commercial or hospital environment Voltage Dips short interruptions and voltage...

Страница 13: ...ngths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment...

Страница 14: ...ower of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73...

Страница 15: ...peration 10 40 Storage 15 50 Shipping 15 70 Environment humidity Operation 10 90 non condensing Storage 10 90 non condensing Shipping 10 90 non condensing Atmospheric Pressure Operation 700 1013 25hPa...

Страница 16: ...alling Patient must be under the constant watch of a caregiver to monitor the patient s movements When the patient needs to transfer out of bed each side can be deflated individually to allow the pati...