STORAGE 

1) Switch off power from main and unplug, separate the pump from the mattress and place the mattress flat.
2) Fold the mattress in two from mattress foot to head.
3) Allow time for air to escape from mattress to reduce storage space.
4) Close the protective cap cover on the quick connector.

MAINTENANCE 

In case of repair, use only original spare parts and accessories.

 

CLEANING AND DISINFECTION 

WARNING! 

Unplug the pump before starting the cleaning procedure. 

1. Clean the mattress with mild soap.
2. Do not immerse or soak pump unit.
3. After cleaning, dry the mattress without direct sunlight exposure.
4. Check that the connection tubes are not obstructed by dust or other object. Use a soft swab to clean the tubes if necessary.

NOTE

 Never use acids, alkalis or solvents such as acetone to clean the mattress.

CONDITIONS OF DISPOSAL 

General conditions of disposal

 

Dispose the device in the appropriate disposal areas for recycling. 

At the end of its life, the products must not be disposed of along with other domestic waste. 
Dispose this equipment by bringing it to a specific recycling point for electric and electronic equipment or 
others that provide this service.   

SPARE PARTS/ACCESSORIES 

For spare parts and accessories please contact MedaCure or authorized dealer. 

TROUBLESHOOTING 

If your questions can’t be answered with below information, please contact your local agent directly. They might require a 
technician to take care of the problem. 

No lights on unit 

Check control unit is connect to the mains power supply and   
That the unit is switched on. 
Check quick blow fuse on the control unit or mains plug fuse. 

Low pressure alert 

Check main power to the control unit and that the plug is switched. 
Check mattress air supply connector is connected to the pump unit 
correctly. 
Check CPR connector is connected properly. 
Under the mattress cover check all “T”&”L” connectors are   
connected to the air tubes. 
Check the connector tubes for kinks, crimps or damage. 

Patient’s body is sagging in 
the middle/bottoming out 

Increase the value of the comfort the setting. Wait a couple of   
minutes so pressure can stabilize before making another change. 

Control lock up or “freeze” 

Turn the control unit off and unplug the pump. 
Wait a few minutes and plug the control unit back in. Turn on 
the control unit. 

Содержание Comfort Zone CZ36

Страница 1: ...User Manual FOR MODEL CZ36 CZ36 BIP 8 REPLACEMENT CELL ON CELL MATTRESS 2016 MADE IN CHINA...

Страница 2: ...ORE USE page 6 USE WARNINGS page 6 7 HOW TO USE page 7 HOW TO USE THE CPR DEFLATOR INFLATOR page 7 8 STORAGE page 9 MAINTENANCE page 9 CLEANING AND DISINFECTION page 9 CONDITIONS OF DISPOSAL page 9 Ge...

Страница 3: ...ct for any purpose not indicated in this manual Only qualified personnel trained in the treatment and prevention of bedsores should operate this device MedaCure Inc declines all liability for any cons...

Страница 4: ...nt otherwise injury or damage may occur 2 Consult with physician or therapist to determine the correct adjustment and the correct use of this device 3 Keep the packed kit away from heat sources 4 SERV...

Страница 5: ...ernate keeps mattress firm and always inflated d SEAT FUNCTION To increase pressure in each cell when mattress is in the sitting position COMFORT LOW PRESSURE To increase or decrease airflow for a sof...

Страница 6: ...r 5 Fuse Back 8 Filter 9 Main filter 10 Protective cap of filter 11 Hook 1 Pillow 2 Cover 3 Fixing belt 4 Low air loss holes 5 Male quick connector 6 Protective cap of connector 7 Air tubing 8 Patente...

Страница 7: ...e of a sudden power outage The mattress will temporarily retain air even when the pump is turned off or during a power outage Please note this only temporary The cover sheet protects the cells against...

Страница 8: ...plug the control unit into the ground power supply 7 Do not use the product in case of the following 1 the plug or the cable is damaged 2 the system sounds abnormal or vibrates intensely 3 the control...

Страница 9: ...ng 4 Align the air holes as shown to deflate 1 This mattress includes a Quick Inflate Pump and nozzle attachment 2 Attach the nozzle to the pump as shown 3 Align the air holes on the CPR Insert the Qu...

Страница 10: ...t by bringing it to a specific recycling point for electric and electronic equipment or others that provide this service SPARE PARTS ACCESSORIES For spare parts and accessories please contact MedaCure...

Страница 11: ...emissions CISPR 11 Group 1 The device uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment...

Страница 12: ...to line s 2kV line s to earth 1kV differential mode 2kV differential d Mains power quality should be that of a typical commercial or hospital environment Voltage Dips short interruptions and voltage...

Страница 13: ...ngths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment...

Страница 14: ...ower of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73...

Страница 15: ...peration 10 40 Storage 15 50 Shipping 15 70 Environment humidity Operation 10 90 non condensing Storage 10 90 non condensing Shipping 10 90 non condensing Atmospheric Pressure Operation 700 1013 25hPa...

Страница 16: ...alling Patient must be under the constant watch of a caregiver to monitor the patient s movements When the patient needs to transfer out of bed each side can be deflated individually to allow the pati...

Отзывы: