background image

Il sottoscritto,

________________________________________________________

Thendersigned:

Installatore CERTIFICA di aver eseguito PERSONALMENTE il montaggio del DISPOSITIVO descritto
qui di seguito, conformemente alle istruzioni del fabbricante.
Installed CERTIFIES that the fitting of the DEVICE described below was carried out by him
PERSONALLY, in accordance with the instructions of the manufacturer.

Descrizione del VEICOLO - Description of the VEHICLE:

MARCA,

_____________________MODELLO,

___________________

TRADEMARK:

TYPE:______

NUMERO di SERIE, SERIAL

_________________________________________

NUMBER:_

Applicare nei riquadri le etichette adesive fornite in confezione con i dati indicati e completare il modulo.

___________________________________ Il, On: ____________________

Apply the supplied labels with the relevant data and complete the form.

Installato a, Installed at:

Indirizzo completo dell'installatore,

___________________________________

FIRMA DELL'INSTALLATORE, SIGNATURE:

___________________________________

Full address of installer:

___________________________________

___________________________________

Modello, Type
Matricola, Registration

CERTIFICATO DI INSTALLAZIONE - INSTALLATION CERTIFICATE

TIMBRO, STAMP

NUMERO di IMMATRICOLAZIONE, REGISTRAZION

___________________________

NUMBER:_

Descrizione dell'ALLARME secondo la Norma ECE 97 R

Description of the ALARM as for European Standards 97 R

(Equivalente alla Direttiva Europea 95/56/CE):

(Equivalent to European Directive 95/56/EC):

SENSORE RADAR,
RADAR SENSOR

Yes - Sì

No - No

MED 6000.LW

SIR 050 / SIR 050.NA

ALTRO / OTHER

Rev

.01del29/03/2012-PrintedinIt

aly

AVVERTENZE GENERALI PER L'UTENTE:

DA CONSERVARE A BORDO DEL VEICOLO

!

!

!

L'INSTALLAZIONE deve essere eseguita da PERSONALE QUALIFICATO, secondo le istruzioni specifiche.

A.E.B. S.p.A. declina ogni responsabilità e sospende la GARANZIA in caso di utilizzo improprio del prodotto o di
parte di esso, di manomissione o di abbinamento a dispositivi non previsti.

valido anche per la GARANZIA del prodotto

97 R

L'INSTALLATORE DEVE rilasciare al PROPRIETARIO del veicolo il presente CERTIFICATO DI
INSTALLAZIONE completamente compilato e firmato,

.

L'INSTALLAZIONE di un DISPOSITIVO di ALLARME per veicoli secondo la Norma

comporta:

Il collegamento di TUTTI i pulsanti di porte, cofano e baule, aggiungendo quelli mancanti.
Il collegamento di un AVVISATORE ACUSTICO.
Se è previsto il SENSORE RADAR, deve essere indicato nel presente modulo.

1.
2.
3.

GENERAL WARNINGS FOR THE USER:

PRESERVE INSIDE THE VEHICLE

!

!

!

INSTALLATION must be conducted by QUALIFIED PERSONNEL and according to the instructions.
The INSTALLED MUST provide the OWNER of the vehicle with the present INSTALLATION CERTIFICATE,
completed in full and signed.

.

INSTALLAION of an ALARM DEVICE for vehicles in accordance with the

requires:

The connection of ALL the door, hool, and boot buttons, adding those that are missing.
The connection of an ACOUSTIC SIGNALER.
If the alarm system includes a RADAR SENSOR this must be indicated in the present form.

A.E.B. S.p.A. Declines all responsibility and withdraws the GUARANTEE / WARRANTY in cases of: the improper
use of the product or part there of, tampering with the product, its combination with devices for which it was not
specifically designed.

Valid also for the guarantee of the product

Europea

7 R

1.
2.
3.

n Standard 9

SI PREGA DI SCRIVERE IN STAMPATELLO - PLEASE WRITE IN BLOCK LETTERS

All rights reserved. © 2012

a single member

Company. Subject to changes and incorrect information.

AEB S.p.A.

Tutti i diritti riservati. © 2012 AEB S.p.A. a socio unico
Con riserva di modifiche e di indicazioni errate.

Содержание MED 6000.LW

Страница 1: ... TX PAR LW TX PAR LW SUPPORT MIC LW MIC MEC LW MIC LW MAGNET MIC MEC LW BUTTON MED 6000 LW a socio unico a single member Company Via dell Industria 20 42025 Corte Tegge Cavriago RE Italy med è un marchio is a trademark of Ph 39 0522 494486 Fax 39 0522 494410 e mail service medautomotive it A E B S p A A E B S p A COMPANY WITH QUALITY SYSTEM CERTIFIED BY BUREAU VERITAS ISO 9001 2008 www medautomoti...

Страница 2: ...TX PAR LW ACTIVATING LED ACTIVATING WITHOUT RADAR INFRARED AND CHOKABLE SENSORS PANIC BUTTON DESACTIVATION BUTTON ...

Страница 3: ...e or buzzer If any anomalies or alarms occurred is shown by some additional signalings BEEPS of the siren and by some LED flashings Contact key Ultrasonic sensor it detects all kind of intrusions in the vehicle Opening the doors bonnet or boot connected to the LIGHTBLUE WHITE wire Anti tampering of the ultrasonic sensor anti blinding anti masking Self diagnosis of the system Activating the system ...

Страница 4: ...vehicle and on the accessories installed The maximum transmission range of the wireless sensors roughly 10 meters is reduced in Follow the instructions below to replace the battery A E B S p A declines all responsibility and suspends the warranty in case of any inappropriate use of the product in case of tampering or pairing with inappropriate devices Position the control unit and the wireless sen...

Страница 5: ...indication that the system is activated after approximately The procedure is stopped by placing the key on its socket again by switching the vehicle ignition key on or using a remote control The system activates completely but does not pilot door closing Close the doors with the vehicle s original system original remote control or key 1 Turn the ignition key OFF or with the ignition key OFF open a...

Страница 6: ... for the requested The remote controls that are not used in this operation are disabled Once activated the procedure it is possible to learn the electronic keys 1 With the system in off position enter the EMERGENCYCODE as shown on the PIN CARD 2 TWhen the confirmation BEEPS end and the LED is switched on fixed again within press on the key socket for the metallic part of each Each time pressed the...

Страница 7: ...W when the system is activated opening the door the windows storage compartment etc If when the system is activated the door bonnet windows storage compartment etc is are already open the sensor does not send the alarm To activate the alarm it they must be closed and opened again The alarm cycle is not repeated if the door the windows storage compartment etc is are left open The alarm is repeated ...

Страница 8: ...jects or sunshades in order to avoid false alarms The anti masking and anti blinding function constantly controls the efficiency of the sensors and of their wirings warning in case of any attempts On its activation it checks its correct working conditions and its own parameters in full then it start the vehicle surveillance flashing LED The anomalies if any are signalised by the siren and by the d...

Страница 9: ...ges that follow On every valid pulse the LED switches off temporarily and the buzzer gives 1 BEEP Once terminated the sequence after some seconds the system signals the programming has been accepted giving a two tone signal a series of BEEPS or a musical sequence and the LED is now lit fixed again Short BEEPS and very quick flashings of the LED indicate a denial the made programming does not exist...

Страница 10: ...SIGNALINGSACTIVATION DESACTIVATION 4 Activation standard setting 5 On duty standard setting BUTTON INPUT CUTOFF ACTIVATION Light Blue White wire 6 Activation standard setting SETTING OF THE DOORS LOCKING UNLOCKING TIME 7 1 25 seconds locking unlocking standard setting 8 9 10 FIXED TIMED STATUS SIGNAL 11 Fixed standard setting TIME OF THE STATUS SIGNALIF TIMED 12 10 seconds standard setting 13 14 D...

Страница 11: ...the analogue input of the may be instantaneous or delayed by 30 or 50 seconds for the initial seconds and then it becomes instantaneous It must be delayed when the signal is taken by the delayed switching off internal roof lamp or if are used the additional modules anti lifting high frequency infra red etc The set up depends on the vehicle model and on the paired accessories It has to be kept inte...

Страница 12: ...he and the siren must be connected when the control unit is powered 1 Once in programming mode button of the LED pressed according to the procedure just described which is confirmed by the signals indicated the LED is now lit steady You can now add new sensors in addition to those supplied in the pack which do not have to be paired again as follows 2 Rest the magnet for and move it away from the a...

Страница 13: ...LED is lit steady activate all the sensors to be tested individually for each activation the buzzer and the LED will provide the following indications Beep and blink standard wireless sensor Beeps and blinks close together choked wireless sensor Beeps and blinks close together wireless sensor that sent the last alarm 3 Turn the ignition key and once to end theTEST The test can be carried out as ma...

Страница 14: ... the battery do not touch the circuit or the battery with wet hands Do not attempt to charge dead batteries Do not throw on the fire Do not swallow Dead batteries are to be disposed of in dedicated waste battery containers according to laws currently in force in the individual countries Strictly keep the sensors and the batteries out of children s reach 3V lithium CR 2032 3V lithium CR 123A WARNIN...

Страница 15: ... 7 8 SETTING JUMPER ON OFF LED PULSE COUNT 2 4 WALK TEST FACTORY JUMPER SETTING FOR THE INITIAL TESTS ON OFF LED PULSE COUNT 2 4 WALK TEST CLOSED OPEN OPEN CLOSED The battery can be replaced with the sensor installed JUMPER SETTING FOR CORRECT OPERATION ...

Страница 16: ...ED 5 SETTING JUMPER The battery can be replaced with the sensor installed ON OFF LED PULSE COUNT 2 4 WALK TEST FACTORY JUMPER SETTING FOR THE INITIAL TESTS ON OFF LED PULSE COUNT 2 4 WALK TEST CLOSED OPEN OPEN CLOSED JUMPER SETTING FOR CORRECT OPERATION ...

Страница 17: ...ies and The sirens are homologated in compliance with the concerning the electromagnetic compatibility interferences and noises under the following approval n MED 6000 LW Regulation ECE ONU R97 ECE ONU Regulation 97 ECE ONU Regulation 10 SIR 050 MIC LW MIC MEC LW SEN INFRA LW SEN INFRA360 LW SIR 050 SIR 050 NA European Directive2006 28 EC e24 03 1793 n E 97R A 010061 24 15 WARNING The central unit...

Страница 18: ...erie life about Lithium battery n nominal Temperature range from to Protection IEC 529 1989 DIN 40050 EN 60529 Rolling Code combinations more tha Dimensions x x Life Temperature range from to Protection IEC 529 1989 DIN 40050 EN 60529 Rolling Code combinations more than Feeding voltage nominal Current absorption at rest activated system average values Temperature range from to Protection IEC 529 1...

Страница 19: ......

Страница 20: ...LLAZIONE deve essere eseguita da PERSONALE QUALIFICATO secondo le istruzioni specifiche A E B S p A declina ogni responsabilità e sospende la GARANZIA in caso di utilizzo improprio del prodotto o di parte di esso di manomissione o di abbinamento a dispositivi non previsti valido anche per la GARANZIAdel prodotto 97 R L INSTALLATORE DEVE rilasciare al PROPRIETARIO del veicolo il presente CERTIFICAT...

Отзывы: