eMINI fogger
User Guide, Rev: A/a, April 2020
23 / 28
CABLE
REQUIREMENTS
C
ONNECTION TO THE MAIN
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the
manufacturer, or its distributing / service agent.
•
Operating voltage: 100-250 VAC, single phase. 50/60 Hz, 1415 W nominal (1100-1480 W).
•
Ground / Earth connection
REQUIRED
.
•
Cable:
2 mm
2
(14 AWG), 3-
wire, 105 ˚C copper, 300 V
CE UL/CSA compliant cable
•
Cable Preparation: Da = 9.5 [0.374”]
-
15.0 [0.59”]
•
Cable Assembly
1.
Put bushing and chuck onto the cable
2.
Prepare cable as shown above
3.
Insert the wire into the terminals and fasten the clamping device by a flat screw driver
4.
Push insert and chuck into housing (pay attention to the guiding keyway!)
5.
Fasten bushing by means of a fork wrench ¾”, min. Torque 2.5 Nm (1.8 lb
-ft)
DMX
512
CONNECTION
•
DMX/RDM data:
Dual twisted pair 0.75 mm (22 AWG) + shield, XLR-5 type connector,
CE UL/CSA compliant cable.
•
Wiring XLR Connectors:
1
–
Shield
2 - Signal (-)
3 - Signal (+)
4
–
Not connected
5
–
Not connected