eMINI fogger
User Guide, Rev: A/a, April 2020
15 / 28
If a critical problem occurs, the program shuts down automatically the fogger, and displays an error message
in the
State Menu
(see
Fail State
).
WARNING
Never power off a fogger while it is producing fog
–
See the shut down procedure.
Shut down procedure
Never shut down the MDG
eMINI
fogger while producing fog.
Power off the fogger observing the following sequence:
•
Switch off
the fog emission («CONTROL
FOG
OFF»),
•
Switch the fogger «UNIT OFF» mode («CONTROL
UNIT
OFF»),
•
Power off the
MDG
eMINI
fogger
,
by switching off the “MAIN POWER SWITCH”.
Switching directly the fogger in
«UNIT OFF»
mode by DMX will yield the same result as above. Wait for all
the cycles to complete before powering off the fogger.
FAIL State
FAIL state mode
is initiated if any critical error occurs.
In this state, the
MDG
eMINI
is
off,
awaiting an action from the user.
A critical error is always displayed in the
Status Menu
(«STATUS
ERROR»), as well as the five (5) last
critical errors («STATUS
LAST ERR»).
•
ERROR = HEATER
LAST ERR CODE = 6
This error will occur if the temperature of the heating module is not increasing with the proper thermal
ramp.
This is generally due to a heater cartridge(s) problem. Shut down the fogger and restart it. Check the
heating process with the value of the Status («STATUS
STATE
xx% HEAT»). If the percent is not
increasing, the heater cartridges have failed.
•
ERROR = T. HIGH
LAST ERR CODE = 8
This error will occur if the temperature of the heating module is too high.
This is generally due to an electronic problem. Shut down the fogger and restart it.
Содержание eMINI
Страница 2: ...eMINI fogger User Guide Rev A a April 2020 2 28 Intentionally left blank...
Страница 25: ...eMINI fogger User Guide Rev A a April 2020 25 28 DIMENSIONS...
Страница 27: ...eMINI fogger User Guide Rev A a April 2020 27 28 DECLARATION OF CONFORMITY...
Страница 28: ...eMINI fogger User Guide Rev A a April 2020 28 28 NOTES...