eMINI fogger
User Guide, Rev: A/a, April 2020
17 / 28
DMX
C
ONTROL
The MDG
eMINI
can be controlled via a DMX512-A USITT standard protocol.
WARNING
Activating the
«DMX» mode («INTERFACE
MODE
DMX
»)
, controls the MDG eMINI
only by DMX signal. If the DMX wire is
unplugged
or DMX
signal is lost
, the fogger
initiates an automatic shutdown procedure
.
Activating the
«AUTO» mode («INTERFACE
MODE
AUTO
»)
, controls MDG eMINI
by DMX, only if there is a signal. If the DMX wire is
unplugged
or DMX
signal is lost
, the
fogger
keeps the last DMX values
.
WARNING
In
«
AUTO Mode
»
, DMX commands always take precedence over Local commands.
The MDG
eMINI
provides a simple way to check if there is DMX signal:
The user can change the DMX Start Address in the Interface Menu («
DMX Add
»), and choose any value
between 1 and 510 (512, last DMX channel).
The user can change the DMX Start Address in the Interface Menu («
DMX Add
»), and choose any value
between 1 and 511 (512, last DMX channel).
The fogger uses three (3) DMX channels, but has two different personalities:
•
Channel 1
0 (0%)
UNIT OFF
128 (50%)
UNIT ON
255 (100%)
•
Channel 2
0 (0%)
to
255 (100%)
, FOG OUTPUT (from minimum to maximum)
OR
0 (0.1 s)
to
255 (25.5 s)
, BURST DURATION
•
Channel 3
0 (0%)
FOG OFF
1
28 (50%)
FOG ON
255 (100%)
These channels have the same behaviour that the menus of the local interface (see
Operating instructions
paragraph).
No DMX Signal
DMX Signal
Содержание eMINI
Страница 2: ...eMINI fogger User Guide Rev A a April 2020 2 28 Intentionally left blank...
Страница 25: ...eMINI fogger User Guide Rev A a April 2020 25 28 DIMENSIONS...
Страница 27: ...eMINI fogger User Guide Rev A a April 2020 27 28 DECLARATION OF CONFORMITY...
Страница 28: ...eMINI fogger User Guide Rev A a April 2020 28 28 NOTES...