37
21-SAFETY DEVICES AND ALARMS
Technical Dept. - All rights reserved - Reproduction prohibited
WRITTEN ON THE
DISPLAY
TYPE OF PROBLEM
SOLUTION
A08
FLUE GAS FAN
Faulty smoke fan.
Check that the lower compartment is clean (see the
pages dedicated to stove cleaning) and verify that it is
not obstructed; clean it and cancel the alarm.
If the alarm persists, contact the service centre.
A09
SMOKE SENSOR
Smoke sensor fault.
Contact an authorised service centre to have the
component checked and, if needed, replace the
component.
A11
GEAR REDUCER
Feed screw gear motor fault.
The component is not working regularly.
Contact an authorised service centre to have the
component checked and, if needed, replace the
component.
A13
BOARD TEMP
Electronic board overheating
Wait for the cooling phase to end, cancel the alarm
and reduce pellet loading (SETTINGS MENU - Pellet
recipe). If the alarm persists, contact the service
centre.
A14
ACTIVE SENSOR
Active sensor anomaly
Active Plus sensor operation anomaly. Contact an
authorised service centre to have the component
checked and, if needed, replace the component.
A18
TRIP
Tripped safety devices
Water temperature is too high or thermostat operation
anomaly.
Water pressure too low.
Triggered air pressure switch: check the pressure of the
hydraulic system. Make sure the pellet tank and door
are closed.
If the alarm persists, contact the service centre.
A19
WATER PROBE
Fault with water sensor.
Possible fault in the safety component. Contact an
authorised service centre to have the component
checked and, if needed, replace the component.
A20
AUX PROBE
Auxiliary probe fault
Possible component fault.
Check that the probe inserted in the system respects
the characteristics specified in the instructions (see
external probe).
Contact an authorised service centre to have the
component checked and, if needed, replace the
component.
Содержание EGO-STAR Hydromatic 12