21-SAFETY DEVICES AND ALARMS
ALARM ALERTS
If there is an operational anomaly, the stove enters the alarm phase displaying the problem that has taken place through a code, a brief
description of the alarm type and an acoustic warning.
The following table describes the possible alarms indicated by the stove, associated to the respective code that appears on the panel and
helpful tips to solve the problem.
B = RESET (cancels alarm)
C = INFO (provides information on the alarm type)
E = MENU
WRITTEN ON THE
DISPLAY
TYPE OF PROBLEM
SOLUTION
A01
NO IGNITION
The fire does not ignite.
(without acoustic alarm)
Check the level of pellets in the hopper.
Check that the brazier is correctly positioned in its seat
and has no build-up or unburned material.
Make sure the spark plug warms up.
Thoroughly empty and clean the brazier before
restarting.
A02
NO FLAME
The fire goes out abnormally.
(without acoustic alarm)
Check the level of pellets in the hopper.
Check that the brazier rests correctly in its seat and has
no visible deposits of unburned pellets.
A03
PLT SAFETY
Pellet tank temperature is too high
Wait for the cooling phase to end, cancel the alarm
and reduce pellet loading (SETTINGS MENU - Pellet
recipe). If the alarm persists, contact the service
centre.
A04
FUMES TEMP
Fumes temperature is too high
Wait for the cooling phase to end, cancel the alarm
and reduce pellet loading (SETTINGS MENU - Pellet
recipe). If the alarm persists, contact the service
centre.
A05
OBSTRUCTION
Chimney flue clogged
Verify brazier clogging, smoke duct, lower
compartment and door closing. If the alarm persists,
contact the service centre.
B
E
RESET
C
OBSTRUCTION
A05
MENU
INFO