14
18-INFORMATION MENU
STOVE STATE-INFORMATION
This menu is particularly useful if you want to verify the stove’s working condition (State).
From the OFF screen, press the “E” Menu button, scroll with the “D” arrow key, up to the Information item, press the ok “E” key, scroll again
with the “D” arrow key up to stove state, press OK with the “E” key and one enters the stove State-information menu.
The items available within STOVE-STATE INFORMATION can be viewed using the “C” and “D” arrow keys and are:
state
water temp.
set
aux sensor
set
set
fumes fan
set
feed screw
set
fumes temp.
req
air fan
pump
relay aux
spark plug
modbus com
add.
Auto Stop
• The main stove states that can be read on the display are:
STATE 1-9 various ignition phases
STATE 20-40 work state (power supply)
STATE 60-79 alarm state
STATE 80-92 shut off/cooling/autoeco state
STATE 93-98 auxiliary functions
• WATER TEMP.: Water temperature detected by the probe inside the stove and related SET
• AUX: PROBE: detects the value measured by the aux sensor (external/storage cylinder/puffer)
• .: Value read by the Active Plus system and related SET
• FAN FUMES: Number of fumes fan revolutions and related SET
• FEED SCREW: number of feed screw revolutions and related SET
• FUMES TEMP.: temperature value read by the probe inside the stove
• REQ: (Heating/Domestic) signals if system requires heat
• PUMP: signals if the stove’s internal pump is turned on (ON) or turned off (OFF)
• AUX: RELAY: signals activation (ON) or the OFF state of Auxa relay
• SPARK PLUG: Signals if spark plug is turned on or off
• MODBUS COM. External interface communication state
• ADD.: Address for communicating with modbus
• AUTO STOP: minutes remaining before automatic shutdown for the mechanical brazier cleaning
EXIT
INFORMATIONS-STOVE STATE
STATE = 0-OFF
WATER TEMP = -43°C SET = 70°C
= 471 SET = 400
SMOKE FAN = 0 SET = 0
D
C
EXIT
INFORMATIONS-STOVE STATE
FEED SCREW = 0 SET = 0
SMOKE TEMP = 30°C REQ = BOLL
AIR FAN = 0% POMP. = OFF
3 WAY VALVE = NO HY. CAND. =OFF
C
D
EXIT
INFORMATIONS-STOVE STATE
MODBUS COM. = OFF IND.=4
Содержание EGO-STAR Hydromatic 12
Страница 51: ......