PBXgateway II Quick Installation Guide
46
Meridian PBX Configuration
Termination of the EXTender 3000
In order to use the EXTender 3000 with the PBXgateway II, you first need to configure the second I
channel (CH2) of each PBX port assigned to a remote user. After the PBX is configured, you can then
configure the PBXgateway II for termination of the EXTender 3000 units, as described on page 40.
Note: The PBXgateway II does not support the termination of the EXTender 1000 for the Meridian PBX.
This will be supported in a future release.
Prerequisites for Configuration
•
The PBX should be powered ON and operational.
•
Make sure a basic configuration terminal consisting of a monitor and keyboard is connected to the
PBX via an RS-232 cable.
•
The PBX should have DCP ports assigned to the Gateway II.
Procedure
You first need to configure the first B channel (Ch1).
1. Go to the Meridian maintenance terminal and log in.
2. Enter
LD 11
(overlay). The table below shows an example of the system prompts and the
corresponding responses you need to enter to properly configure the first B1 channel. To view the
changes, enter PRT at the REQ prompt.
3. For each System Response below, enter the User Input.
B1 (Ch 1)
System Response
User Input
REQ
NEW
Note
: You can also use CHG (change) if this is an existing TN.
TYPE 2616
TN 2
0
DATE
PAGE
DES ENG
TN
002 0 00 00
TYPE 2616
CDEN 8D
CUST 0
AOM 0
FDN
7000
Not
e: Example of Voice Mail DN shown
TGAR 0
LDN NO
NCOS 0
SGRP 0
RNPG 00
SCI
SSU