PBXgateway II Quick Installation Guide
39
14. Perform a
display station
on extension Ch1 to certify that all changes have been saved. Ensure that
all
appearances are bridged to the office extension and that an Analog Adjunct to extension Ch2
exists.
15. Done. The DEFINITY PBX is now configured to support
one
user.
SCENARIO #2: Only ConneX Phone Is Used
Provisioning a new extension for the ConneX Phone.
1. Provision an extension for the ConneX phone (Ch1) on the DEFINITY. Wire this extension into the
RemoteConneX PBXgateway on an available port.
2. Go to Page 1 of the DEFINITY terminal session to configure the Ch1 extension.
3. Change
Type
to a DEFINITY phone set that supports the “analog adjunct” feature. We recommend
phone set
8411D
, however other phone types like the
6416D+
and
6424D+
also support the analog
adjunct feature. Notice the
Data Option
field appears in the middle of the screen when this change is
made.
4. Enter
the
Name
field. Be sure to give this extension a clear name (i.e. ConneX – Port 1).
5. Change
Data Option
to
analog
. Notice the page number increases by 1 when this change is made.
6. Go to last page (
Note: last page number may vary depending on phone model).
Heading should read
Analog Adjunct.
7. On last page: Assign the
Data Extension
a new or unused extension (Ch2) on the DEFINITY. This is
the extension number that the ConneX users will call to access RCX. This will be either a DID
extension, or accessible through a transfer from a main number (i.e. Intuity, Vector, IVR,etc.).
8. Type in the extension
Name
. Give this extension a descriptive name so it is clear what it is being
used for (i.e. Username B2 - Mobile #1).
9. Set
the
call-appr
field to
Y
.
10. Perform a
display station
on Ch1 extension to verify that all changes have been saved. And ensure
that an Analog Adjunct to the corresponding Ch2 extension exists.
11. Done. The DEFINITY PBX is now configured to support
one
user.
Meridian PBX ConneX Configuration
These instructions are applicable for the configuration of Nortel’s Meridian PBX running release 22 or
higher:
SCENARIO #1: Office Phone Used in Conjunction with the ConneX Phone
There is only one change required on the user’s office Terminal Number (TN) when he/she wishes to use
the ConneX phone as a complementary business tool. The number of rings should be increased to six
(06) before going into voicemail. This is required to allow enough time for the gateway to call the mobile
phone.
Note: No wiring changes are required on this TN.
1. On the Meridian maintenance terminal, go to
>LD 15
(a.k.a. overlay) to change the (Call Redirection)
RDR_DATA
field to
YES
and set (Call Forward No Answer)
CFN2
to
6
rings.
2. Go
to
>LD 11
to
CHG (Change)
the (Ringing Cycle Option for Call Forward No Answer)
ITEM RCO
to
2 (for example RCO 2= the phone will ring six times before going into voicemail)
.
Tech Tip
: Create a
new RCO profile for mobile users. Six rings are recommended for this new profile.
3. On
>LD 11
,
program a Ringing Pickup Group (
RNPG
) value for this TN when prompted.
4. Set the Class of Service to Call Forward No Answer allowed (FNA)
ITEM CLS
to
FNA.