EXTender 6000 Quick Installation Guide
28
IP Network (RVP_IP)
This section of the manual provides the necessary information to configure the EXTender for connection
within an IP network.
Note: The units are programmed at the factory with RVP_Direct “default” settings. The Type parameter
must be set to RVP_Over_IP
.
IP Network
Branch Office
Punch Block
EXTender 6000
Punch Block
PBX
Corporate Office
PBXgateway
Ethernet
RJ21
Ethernet
Figure 17: RVP_IP Typical Installation
Prerequisites for Configuration
•
The Gateway (at the corporate site) and the EXTender (at the branch office) must be installed
properly and the network link between both devices must be operational.
•
The network administrator must assign IP address information for both units.
TCP/UDP Requirements
Ensure that the correct TCP/UDP ports have been opened to allow the EXTender to connect to the
Gateway through your company firewall. The following TCP/UDP port requirements must be met:
The EXTender 6000 uses even numbered ports 12,288 to 12,544. The port numbers start at 12,288 and
increment by 2 to the total number of ports used. For example, if you have an 8 port EXTender 6000 with
3 telephones connected, ensure that ports 12,288, 12,290, and 12,292 are opened.
The Gateway unit uses TCP/UDP port 2698.
Basic Configuration
Table 8:
RVP_IP Basic Configuration Steps
You must …
to…
Refer
to…
Set Connect Parameters
Configure the Remote Unit to communicate over
the IP net-work.
page 29
Set IP Parameters
Configure the Remote Unit with required IP
information.
page 30