6.5 Warning messages
Chamber open
This screen is displayed when either the left or right door
latch sensor is detected open.
AUTO mode cannot be selected when the chamber is open.
If the chamber opens inadvertently during an automatic
cycle, a warning beeper will sound to alert the operator.
Drop floor sensor
As soon as the drop floor moves away from the working
position, this warning will be displayed to alert the operator.
The red light beside button 7 will also flash.
(2002)
Knife pressure too high (V6750 only)
This is displayed when the knife pressure is too high for
baling (above 65 bar hydraulic pressure).
It is normal for this warning to be displayed during knife
activation with maximum tractor pressure. It must be
lowered again before baling.
(2003)
Bale not ejected
This screen is always shown as soon as the chamber is
opened after binding. As the bale ejects from the chamber
and rolls off the kicker, a beep will sound and the bale image
will disappear to indicate that the chamber door can be
closed.
Track motor
This is shown if there is a track motor fault. This will also be
displayed if the track has gone too far towards the edge or
the centre of the bale.
(2101)
Содержание Twiner
Страница 2: ...This page is intentionally left blank ...
Страница 5: ...McHale Twiner 5 This page is intentionally left blank ...
Страница 21: ...McHale Twiner 21 This page is intentionally left blank ...
Страница 29: ...McHale Twiner 29 6 3 4 Menu structure ...
Страница 42: ...V Series Menu structure twine ...