2 - 3
Diesel Engine
Read the operating and maintenance instructions for the engine
before operating.
The engine is a 3 cylinder water cooled design. It uses an
electric fuel pump located near the fuel tank.
The throttle control and key switch are at the rear of the
machine. Turn the key switch to the left to preheat the glow
plugs and then to the right to start the engine.
The engine is equipped with an oil pressure switch and coolant
temperature switch that will sound an alarm at low oil pressure
or coolant temperatures exceeding 230°F.
If you hear the alarm while operating the machine, turn the machine
off and check oil level. If oil is at proper level, wait for machine
to cool and then check coolant level and mixture.
The fuel shut off valve is located on the engine mounted fuel
filter.
TX02542-9-15-05
CD018
58-11-16
-16
CD017
90
-0
8-17
-16
Operator Panel
A - Key switch -
Switch to start and stop the machine.
B - Wait Light -
Indicate the engine is pre-heating and
will turn off once engine pre-heat is complete.
C - Hour Meter -
With the key switch in the run position,
total hours of operation are displayed.
D - Track Controls -
Used to control the movement of the
left and right tracks.
E - Engine Throttle Control -
Adjust the engine speed from
low to high.
TX05160-09-22-16
CD018
49-0
9-
21-16
A
B
D
E
C