Specifications
7 - 1
McElroy DataLogger
™
DAP PC9800 Environmental Ratings
:
Rain: 50” (127 cm)
Dust: 60” (152 cm)
Heat: 67” (170 cm)
Cool: 76” (193 cm)
Operating Temperature:
The recommended temperature range, where the DataLogger may be used, is from - 30°C to +
50°C (-22°F to +122°F).
A short exposure to temperatures lower or higher than these could possibly make the screen
very dark or light until the unit returns within the suggested temperature range.
Long exposure to temperature below - 40°C (- 40°F) may damage the screen. Prolonged
exposure to temperatures above +60°C (+140°F)will damage the main battery and above
+70°C may damage the unit (+158°F).
DAP PC9800 Computer Specification
:
80386 microprocessor
200 x 200 pixel LCD display
MS-DOS operating system
2MB battery-backed SRAM
4MB NAND memory
Temperature Probe
:
Range:
350° - 540° F
Accuracy:
≤ ±
10° F Accuracy not guaranteed below 350°
Pressure Probe
:
Range:
0 to 2000 psi
Accuracy:
≤
100PSI:
±
2 PSI
>
100 PSI:
±
1%
TX01918-5-2-01