5 - 3
Operation
Measuring the Heater Temperature Using The
DataLogger
™
Probe
Follow the instructions on the screen to measure the heater plate
surface temperature. Remove the temperature probe from the
storage location on the DataLogger
™
and place the metal tip flat
on the surface of the heater plate. Read the heater plate
temperature on the screen. Press ENTER to record the measured
heater temperature while still holding the probe on the heater
plate.
NOTICE:
Remove the probe from the plate as soon as possible.
Excessive heating of the probe will cause an inaccurate reading.
NOTICE:
Make sure the probe is not at an angle when
measuring the temperature. Incorrect probe placement will result
in measurement errors.
NOTICE:
Keep the lens on the temperature probe clean. If the lens
is dirty, it will give an inaccurate reading.
When finished measuring the heater temperature, return the
probe to the holder on the DataLogger
™
. Press the probe onto the
plastic strip firmly to secure the probe.
Using an External Source For
Measuring Heater Temperature
When using an external probe for measuring heater temperature,
key in the measured value instead of using the Datalogger
™
probe.
TX01372-5-19-97
TX01373-5-19-97
PH01171-6-9-97
170 Heater Temp.:
External: °F
Datalogger: 0°F
Use numeric keys
Press <ENTER> when done
Содержание DataLogger
Страница 1: ...Manual DL3601 Revision B 11 02 Fusion Joint DataLogger Operator s Manual...
Страница 39: ......