Installation and use
SEEDER MONITOR MCK 1200
21
8. Technical data
8.1 Seeder Monitor MCK 1200
Power supply voltage
: da 10 a 16 Vdc
Max. energy consumption 16Vdc
(not including photocells)
: 420 mA
Functioning characteristics
Protection degree
: IP 65 on the front
Mechanic vibrations resistance
: 2 g random
Functioning conditions
Room temperature
: -20°C / +70°C
Weather conditions
: Relative humidity 90%
Transport and storage
Temperature
: -25°C / +85°C
8.2 Technical data accessories
8.2.1 Speed sensor D.18 cod. 481
Power supply voltage
: 8 VDC
Output signal
: NAMUR
Max. working frequency
: 1000 Hz
Working temperature
: - 25°C / +75°C
Max. operation distance
: from 0 a 4 mm
Protection degree
: IP 67
8.2.2 Photocell sensor cod. 4228
Power supply voltage
: from 8 VDC to 10 VDC
Output signal
: NPN-NO
Max. working frequency
: 200 Hz
Working temperature
: - 25°/+70°C
Max. operation distance
: 40
�
80 mm
Pickup angle range
: 25°
Protection degree
: IP 68