– DR05 – 23.03.2017
Label
Description
COM 1
Configuration options for COM1 interface
The settings that follow it apply only to this interface.
Interface Type
Use this drop-down field to set the interface type for COM1. The options are as follows:
RS232, RS485 2-wire, RS485 4-wire, RS422
Drivers
Driver
from
list:
Select a product/brand-specific driver to control your serial device.
User
settings
: If no suitable driver is available or you need to enter your own configuration
parameters. These can be entered manually.
Baud
rate
: Enter the baud rate for communication here.
Data
format
: Select one of the settings for data bits, parity or stop bits
Handshake
: Select a handshake (flow control) option.
Receive
loops
: This is a start counter for serial signals, i.e. how many cycles the sys-
tem goes through until it sends the data packet.
Driver
Select the driver that you want to load. Device drivers can be selected for the following
brands:
AllanBradley, AMK, ASB, AtlasCopco, Baumüller, Berger, Bosch, B&R, DanfossVLT, Elau, F-
Tron,GE_Fanuc, Hitachi, I-for-T, Indramal, IQ2000, KEB; Kuhnke, KEB, Lauer, Lenze, Locon,
Micro_Innovation, Mitshubishi, Möller, Motoman, Npos, Omron, Parker Hauser CompaxC3,
Phoenix, Pilz, PLC Direct, Primo, Proface, Promicon, Quin, SCS Automata, Seidel Kollmor-
gen, SEW, Siemens, Stoeber, Stromag, Sütron, Tsx37, Tsx47, Tsx57, Vectron, Vega Sensor,
Voelkel Grenzlastregler, Winloc
Protocol
Select the protocol for communicating with the connected device. Options are: TCP and UDP
Port
Enter the port that will be used for communication.
Enable ports
through fire-
wall
Checking this box means that you can access the serial devices via the public address
through the port assigned above, without being blocked by the firewall.
MPI/PROFIBUS Interface
17.2.1
Serial interfaces (continued)
Содержание mbNET MDH 810
Страница 12: ...Page 12 of 226 Version 3 3 5 DR05 23 03 2017 4 Technical Data...
Страница 135: ...Page 135 of 226 Version 3 3 5 DR05 23 03 2017 RS232 485 serial interfaces 17 2...
Страница 144: ...Page 144 of 226 Version 3 3 5 DR05 23 03 2017 Add PC PG station 17 4 5 Now you need to add a PC PG station...
Страница 201: ...Page 201 of 226 Version 3 3 5 DR05 23 03 2017 NAT 22 3 1 2...
Страница 202: ...Page 202 of 226 Version 3 3 5 DR05 23 03 2017 Status Modem 22 4 Note Not available at mbNET variants with WLAN...
Страница 214: ...Page 214 of 226 Version 3 3 5 DR05 23 03 2017 23 Extras LUA 23 1 You can activate LUA to write and execute LUA scripts...