9
Electrical Connections
A wiring diagram is located behind the control panel with
connection data.
If local codes permit, power to the dryer can be made by the
use of a flexible UL listed power cord/pigtail (wire size must
conform to rating of dryer), or the dryer can be hard wired
directly to the service breaker panel. In both cases, a strain relief
must be installed where the wiring enters the dryer.
Single-Phase (1ø) Wiring Connections / Hookup
The electrical input connections are made into the rear service
box located at the top of the dryer. To gain access, the service
box cover must be removed. (Refer to the specification drawing
in “Specifications” section of manual.)
120 Volt Application with Neutral
Remove 3 screws holding down electrical box plate at the top
of the machine.
Remove 2 knockouts provided just in front of electrical box and
insert 3/4" UL listed strain relief into the holes.
Insert the wiring from the two 120 V 15 A circuits (one for top
tumbler and one for bottom tumbler) into the strain reliefs.
Determine the top pocket electrical connections by checking
wire label, which will be marked “top”.
Connect wiring from 120 V 15 A circuit to top pocket wiring as
described in the following illustration (black to black, white to
white and green to chassis ground wire).
Connect wiring from 120 V 15 A circuit to remaining wires
(bottom pocket) as described in the following illustration (black
to black, white to white and green to chassis ground wire).
Tighten strain relief screws assuring to leave a 1/2" of slack in
box.
Replace electrical box plate by inserting 3 screws previously
removed.
Single-Phase Electrical Connection Leads
Black
+
Positive or L1
White
+
Neutral or L2
Green
+
Ground
Input connection wiring must be sized properly to handle the
dryer’s current draw. This information is printed on the dryer’s
data label.
Fire Hazard
Use appropriate gauge of copper wire (See chart in
"Electrical Requirements" section).
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Electrically ground appliance per installation
instructions.
Securely tighten all connections.
Failure to do so can result in death, fire, or electrical
shock.
BL
AC
K
BL
AC
K
B
LA
C
K
W
H
IT
E
W
HIT
E
WH
ITE
W
H
IT
E
BL
AC
K
G
R
OU
N
D
G
ROU
N
D
GR
O
UN
D
Gas Information ________________
WARNING
Explosion Hazard
Use a new approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 13" (330 mm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Type of Gas
This dryer is equipped for use with natural gas. It is design
certified by CSA International for Propane and butane gases
with appropriate conversion (Propane kit 887299). No attempt
shall be made to convert the dryer from the gas specified
on the serial/rating plate for use with a different gas without
consulting the serving gas supplier. Conversion must be done
by a qualified service technician.
It is your responsibility to have all plumbing connections,
materials, and workmanship conform to local and state
regulations or codes of the country of destination. In the
absence of such codes, all plumbing connections, materials,
and workmanship must conform to the applicable local
requirements. In the USA this is the National Fuel Gas Code
ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian
Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or
CAN/CGAB149.2-M91 (Propane Gas) or LATEST EDITION.