9

Electrical Connections

A wiring diagram is located behind the control panel with 

connection data.
If local codes permit, power to the dryer can be made by the 

use of a flexible UL listed power cord/pigtail (wire size must 

conform to rating of dryer), or the dryer can be hard wired 

directly to the service breaker panel. In both cases, a strain relief 

must be installed where the wiring enters the dryer.

Single-Phase (1ø) Wiring Connections / Hookup

The electrical input connections are made into the rear service 

box located at the top of the dryer. To gain access, the service 

box cover must be removed. (Refer to the specification drawing 

in “Specifications” section of manual.)

120 Volt Application with Neutral

Remove 3 screws holding down electrical box plate at the top 

of the machine.
Remove 2 knockouts provided just in front of electrical box and 

insert 3/4" UL listed strain relief into the holes.
Insert the wiring from the two 120 V 15 A circuits (one for top 

tumbler and one for bottom tumbler) into the strain reliefs.
Determine the top pocket electrical connections by checking 

wire label, which will be marked “top”.
Connect wiring from 120 V 15 A circuit to top pocket wiring as 

described in the following illustration (black to black, white to 

white and green to chassis ground wire).
Connect wiring from 120 V 15 A circuit to remaining wires 

(bottom pocket) as described in the following illustration (black 

to black, white to white and green to chassis ground wire).
Tighten strain relief screws assuring to leave a 1/2" of slack in 

box.
Replace electrical box plate by inserting 3 screws previously 

removed.

Single-Phase Electrical Connection Leads

Black  

+  

Positive or L1

White  

+  

Neutral or L2

Green  

+  

Ground

Input connection wiring must be sized properly to handle the 

dryer’s current draw. This information is printed on the dryer’s 

data label.

Fire Hazard

Use appropriate gauge of copper wire (See chart in 
"Electrical Requirements" section).
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Electrically ground appliance per installation 
instructions.
Securely tighten all connections.
Failure to do so can result in death, fire, or electrical 
shock.

BL

AC

K

BL

AC

K

B

LA

C

K

W

H

IT

E

W

HIT

E

WH

ITE

W

H

IT

E

BL

AC

K

G

R

OU

N

D

G

ROU

N

D

GR

O

UN

D

Gas Information ________________

WARNING

Explosion Hazard

Use a new approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make 

sure gas pressure does not exceed 13" (330 mm) water 

column. 
Examples of a qualified person include: 
licensed heating personnel, 

authorized gas company personnel, and

authorized service personnel.
Failure to do so can result in death, explosion, or fire.

Type of Gas

This dryer is equipped for use with natural gas. It is design 

certified by CSA International for Propane and butane gases 

with appropriate conversion (Propane kit 887299). No attempt 

shall be made to convert the dryer from the gas specified 

on the serial/rating plate for use with a different gas without 

consulting the serving gas supplier. Conversion must be done 

by a qualified service technician.
It is your responsibility to have all plumbing connections, 

materials, and workmanship conform to local and state 

regulations or codes of the country of destination. In the 

absence of such codes, all plumbing connections, materials, 

and workmanship must conform to the applicable local 

requirements. In the USA this is the National Fuel Gas Code 

ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian 

Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or 

CAN/CGAB149.2-M91 (Propane Gas) or LATEST EDITION.

Содержание MLG30

Страница 1: ...MLG30 Installation Manual Stack Dryer WFR113543E RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Страница 2: ...N HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or...

Страница 3: ..._ HVAC Heating Ventilating and Air Conditioning in WC Inches of Water Column UL Underwriters Laboratory NPT National Pipe Thread Table Of Contents ______________ Caution Label all wires prior to disco...

Страница 4: ...kg APPROXIMATE SHIPPING WEIGHT 710 lb 322 kg AIRFLOW PER POCKET 400 cfm 11 3 cmm HEAT INPUT PER POCKET 72000 Btu hr 18143 kcal hr EXHAUST CONNECTION DIAMETER 8 20 3 cm INLET PIPE CONNECTION PER POCKE...

Страница 5: ...nform to applicable Canadian Standards CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 Propane Gas or LATEST EDITION for General Installation and Gas Plumbing The operation of this dryer may affe...

Страница 6: ...r 1 000 Btu 252 kcal It is not necessary to have a separate make up air opening for each dryer Common make up air openings are acceptable However they must be set up in such a manner that the make up...

Страница 7: ...elbows used exceeds the above noted specifications the cross sectional area of the ductwork may need to be increased IMPORTANT For extended ductwork runs the cross section area of the ductwork can onl...

Страница 8: ...RICAL SERVICE SPECIFICATIONS PER POCKET NOTES A When fuses are used they must be dual element time delay current limiting class RK1 or RK5 ONLY Calculate determine correct fuse value by applying eithe...

Страница 9: ...onnection wiring must be sized properly to handle the dryer s current draw This information is printed on the dryer s data label Fire Hazard Use appropriate gauge of copper wire See chart in Electrica...

Страница 10: ...country of destination and if in doubt the installer must contact the supplier The manufacturer of this dryer does not recommend the use of flexible gas supply line hose Pipe joint compounds that res...

Страница 11: ...immediately upstream of the dryer Test all connections for leaks by brushing on a soapy water solution liquid detergent works well 3 4 x 1 2 x 1 2 TEE 19 05 mm x 12 7 mm x 12 7 mm SEE IMPORTANT NOTE...

Страница 12: ...ry adjustments have been made the dryer must be operated in a heating cycle to verify that the pressure is correct 6 Feed manometer hose through an opening in the back panel while reattaching the back...

Страница 13: ...uctions __________ The dryer is available for use when the appropriate side of the microprocessor display reads 0 minutes and the amount needed to start the dryer i e 25 Once the load has been put int...

Страница 14: ...y lint buildup Suggested Cleaning Schedule Every Third or Fourth Load Clean the lint screen every third or fourth load A clogged lint screen will cause poor dryer performance The lint door drawer is l...

Страница 15: ...Gives the number drill size used 6 Electric Service This describes the voltage and current rating for a particular model 7 Gas Manifold Pressure For Gas Dryers This describes the manifold pressure ta...

Страница 16: ...MLG30 Manuel d installation S cheuse superpos e CONSERVER CES INSTRUCTIONS POUR R F RENCE ULT RIEURE...

Страница 17: ...ce ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas tou...

Страница 18: ...on et Climatisation po CE Pouces de colonne d eau UL Underwriters Laboratory NPT National Pipe Thread Attention Lors des contr les d entretien placer des tiquettes sur l ensemble des c bles avant leur...

Страница 19: ...UEMENT APPROXIMATIF 710 lb 322 kg D BIT D AIR PAR S CHEUSE 400 pi min 11 3 m3 min ENTR E DE CHALEUR PAR S CHEUSE 72 000 Btu h 18 143 kcal h RACCORD D VACUATION DIAM TRE 8 po 20 3 cm RACCORD D ENTR E D...

Страница 20: ...z naturel ou CAN CGA B149 2 M91 gaz propane ou la DERNI RE DITION pour l installation g n rale et la plomberie au gaz L utilisation de cette s cheuse peut affecter celle d autres s cheuses gaz dont la...

Страница 21: ...uverture d air d appoint distincte pour chaque s cheuse Les ouvertures communes pour l air d appoint sont acceptables Toutefois elles doivent tre install es de sorte que l air d appoint est distribu u...

Страница 22: ...onduit IMPORTANT Pour les conduits de longueur prolong e l aire de la section transversale du conduit ne peut tre augment e que dans une certaine mesure Lorsque le nombre de conduits approche les limi...

Страница 23: ...fusibles sont utilis s ils doivent comporter deux l ments tre temporis s de type limiteur de courant classe RK1 ou RK5 UNIQUEMENT Calculez d terminez la bonne valeur de fusible conforme aux codes lec...

Страница 24: ...du circuit de 120 V 15 A au conducteurs restants s cheuse inf rieure comme d crit dans l illustration suivante noir noir blanc blanc et vert au fil de terre du ch ssis Serrer les vis du r ducteur de t...

Страница 25: ...heuse l usine Le r glage ou la conversion des s cheuses sur le terrain pour des altitudes sup rieures 2 000 pi 610 m est effectu en changeant chaque orifice du br leur Si cette conversion est n cessai...

Страница 26: ...les raccordements pour la pr sence des fuites en appliquant une solution d eau savonneuse le d tergent liquide fonctionne bien RACCORD EN T DE 3 4 po x 1 2 po x 1 2 po 19 05 mm x 12 7 mm x 12 7 mm VO...

Страница 27: ...ns le sens antihoraire pour abaisser la pression REMARQUE La pression de sortie est mesur e pendant que le br leur est en marche pour toutes les conditions de r glage du br leur Par cons quent une foi...

Страница 28: ...fi s en cours de route ou en raison de conditions d emplacement marginales installation Mettre sous tension la s cheuse Voir les instructions d installation pour mettre la s cheuse en marche Ouvrir to...

Страница 29: ..._________________ R paration La r paration doit tre effectu e par un technicien ou une entreprise de r paration ayant les qualifications requises ou par le fournisseur de gaz Si une r paration est n c...

Страница 30: ...VEC DES ELEVATIONS ENTRE 610 A 1372M Assembled in Assemble aux USA Whirlpool Corporation TEL 269 923 3000 88 Currant Road FAX 508 678 9447 Fall River MA 02720 4781 mdl service whirlpool com WWW WHIRLP...

Страница 31: ...31...

Страница 32: ...WFR113543E 03 20 TM 2020 Maytag All rights reserved Tous droits r serv s...

Отзывы: