Gas Pressure Test Procedure

1. 

Disconnect power to the dryer.

2. 

Turn off gas supply using the shutoff valve that supplies the 

dryer.

3. 

Remove the back panel from the dryer.

4. 

Locate the output pressure tap screw on the gas valve and 

unscrew 4 to 5 full turns.

5. 

Connect the airtight hose to pressure tap post. (Airtight hose 

will attach between pressure tap post and manometer).

6. 

Feed hose through an opening in the back panel while 

reattaching the back panel to the dryer.

7. 

Connect opposite end of hose to manometer.

8. 

Turn on gas supply using the shutoff valve that supplies the 

dryer and reconnect the power.

9. 

Start the dryer in Heat Mode and wait for ignition.

10. 

Record the manometer reading. Check the reading against 

the Burner Pressure column in the Gas Specification chart 

on page 11. Measured value should be within .30" W.C. 

of that value. If not, see the next section on Gas Pressure 

Adjustment.

11. 

Once test is complete, disconnect power to the dryer.

12. 

Turn off gas supply using the shutoff valve that supplies the 

dryer.

13. 

Remove the back panel from the dryer.

14. 

Disconnect manometer.

15. 

Remove hose from pressure tap post. Tighten screw inside 

the pressure tap or install plug.

Gas Pressure Adjustment

1. 

Disconnect power to the dryer.

2. 

Turn off gas supply using the shutoff valve that supplies the 

dryer.

3. 

Disconnect the manometer and remove the back panel from 

the dryer.

4. 

Locate and remove the regulator cap with a screwdriver to 

gain access gas valve’s internal regulator adjusting screw.

5. 

Use a small flat blade screwdriver to turn the plastic 

adjustment screw in the valve. Turn the screw clockwise to 

raise pressure and counterclockwise to lower pressure.

NOTE:

 Outlet pressure is measured with the burner in 

operation for all burner adjustment conditions. Therefore, 

once the necessary adjustments have been made, the 

dryer must be operated in a heating cycle to verify that the 

pressure is correct.

6. 

Feed manometer hose through an opening in the back panel 

while reattaching the back panel to the dryer.

7. 

Connect opposite end of hose to manometer.

8. 

Turn on gas supply using the shutoff valve that supplies the 

dryer and reconnect the power.

9. 

Run the dryer and check the outlet pressure. If the pressure 

is not correct, discontinue the power to the dryer and repeat 

steps 1 thru 8. Do this as many times as necessary to 

achieve the correct burner pressure.

10. 

Once the adjustment of the valve is complete, the regulator 

cap must be replaced and sealed with, for example, paint to 

prevent tampering by the user.

Leak Check

1. 

Be sure the gas supply is turned on.

2. 

Turn on dryer.

3. 

Brush or spray an approved noncorrosive leak-detection 

solution onto all connections and inspect for leaks indicated 

by growing bubbles.

4. 

If dryer was moved during testing, use the same method 

to check for leaks in the flexible gas supply line and fittings 

between the dryer and the gas supply pipe.

5. 

If any bubbles are present, turn off gas supply, tighten the 

leaking connection and retest for leaks.

Preparation for Operation /  

Start-Up ______________________

The following items should be checked before attempting to 

operate the dryer:

 

͜

Read all “DANGER”, “WARNING”, “CAUTION”, and 

“DIRECTION” labels attached to the dryer.

 

͜

Read all instructions before using the dryer.

 

͜

Check incoming supply voltage to be sure that it is the same 

as indicated on the data label.

 

͜

Be sure that all gas shutoff valves are in the open position.

 

͜

Be sure all back panels (guards) and electric box covers are 

in place.

 

͜

Be sure the service doors are closed and securely in place.

 

͜

Be sure the lint door/drawer is securely in place.

 

͜

Rotate the tumbler (drum) by hand to be sure it moves freely.

 

͜

Check bolts, nuts, screws, terminals, and fittings for 

tightness and security.

 

͜

Check that the vent is connected to the dryer and is 

exhausted to the outdoors.

Содержание MLG30

Страница 1: ...MLG30 Installation Manual Stack Dryer WFR113543E RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Страница 2: ...N HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or...

Страница 3: ..._ HVAC Heating Ventilating and Air Conditioning in WC Inches of Water Column UL Underwriters Laboratory NPT National Pipe Thread Table Of Contents ______________ Caution Label all wires prior to disco...

Страница 4: ...kg APPROXIMATE SHIPPING WEIGHT 710 lb 322 kg AIRFLOW PER POCKET 400 cfm 11 3 cmm HEAT INPUT PER POCKET 72000 Btu hr 18143 kcal hr EXHAUST CONNECTION DIAMETER 8 20 3 cm INLET PIPE CONNECTION PER POCKE...

Страница 5: ...nform to applicable Canadian Standards CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 Propane Gas or LATEST EDITION for General Installation and Gas Plumbing The operation of this dryer may affe...

Страница 6: ...r 1 000 Btu 252 kcal It is not necessary to have a separate make up air opening for each dryer Common make up air openings are acceptable However they must be set up in such a manner that the make up...

Страница 7: ...elbows used exceeds the above noted specifications the cross sectional area of the ductwork may need to be increased IMPORTANT For extended ductwork runs the cross section area of the ductwork can onl...

Страница 8: ...RICAL SERVICE SPECIFICATIONS PER POCKET NOTES A When fuses are used they must be dual element time delay current limiting class RK1 or RK5 ONLY Calculate determine correct fuse value by applying eithe...

Страница 9: ...onnection wiring must be sized properly to handle the dryer s current draw This information is printed on the dryer s data label Fire Hazard Use appropriate gauge of copper wire See chart in Electrica...

Страница 10: ...country of destination and if in doubt the installer must contact the supplier The manufacturer of this dryer does not recommend the use of flexible gas supply line hose Pipe joint compounds that res...

Страница 11: ...immediately upstream of the dryer Test all connections for leaks by brushing on a soapy water solution liquid detergent works well 3 4 x 1 2 x 1 2 TEE 19 05 mm x 12 7 mm x 12 7 mm SEE IMPORTANT NOTE...

Страница 12: ...ry adjustments have been made the dryer must be operated in a heating cycle to verify that the pressure is correct 6 Feed manometer hose through an opening in the back panel while reattaching the back...

Страница 13: ...uctions __________ The dryer is available for use when the appropriate side of the microprocessor display reads 0 minutes and the amount needed to start the dryer i e 25 Once the load has been put int...

Страница 14: ...y lint buildup Suggested Cleaning Schedule Every Third or Fourth Load Clean the lint screen every third or fourth load A clogged lint screen will cause poor dryer performance The lint door drawer is l...

Страница 15: ...Gives the number drill size used 6 Electric Service This describes the voltage and current rating for a particular model 7 Gas Manifold Pressure For Gas Dryers This describes the manifold pressure ta...

Страница 16: ...MLG30 Manuel d installation S cheuse superpos e CONSERVER CES INSTRUCTIONS POUR R F RENCE ULT RIEURE...

Страница 17: ...ce ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas tou...

Страница 18: ...on et Climatisation po CE Pouces de colonne d eau UL Underwriters Laboratory NPT National Pipe Thread Attention Lors des contr les d entretien placer des tiquettes sur l ensemble des c bles avant leur...

Страница 19: ...UEMENT APPROXIMATIF 710 lb 322 kg D BIT D AIR PAR S CHEUSE 400 pi min 11 3 m3 min ENTR E DE CHALEUR PAR S CHEUSE 72 000 Btu h 18 143 kcal h RACCORD D VACUATION DIAM TRE 8 po 20 3 cm RACCORD D ENTR E D...

Страница 20: ...z naturel ou CAN CGA B149 2 M91 gaz propane ou la DERNI RE DITION pour l installation g n rale et la plomberie au gaz L utilisation de cette s cheuse peut affecter celle d autres s cheuses gaz dont la...

Страница 21: ...uverture d air d appoint distincte pour chaque s cheuse Les ouvertures communes pour l air d appoint sont acceptables Toutefois elles doivent tre install es de sorte que l air d appoint est distribu u...

Страница 22: ...onduit IMPORTANT Pour les conduits de longueur prolong e l aire de la section transversale du conduit ne peut tre augment e que dans une certaine mesure Lorsque le nombre de conduits approche les limi...

Страница 23: ...fusibles sont utilis s ils doivent comporter deux l ments tre temporis s de type limiteur de courant classe RK1 ou RK5 UNIQUEMENT Calculez d terminez la bonne valeur de fusible conforme aux codes lec...

Страница 24: ...du circuit de 120 V 15 A au conducteurs restants s cheuse inf rieure comme d crit dans l illustration suivante noir noir blanc blanc et vert au fil de terre du ch ssis Serrer les vis du r ducteur de t...

Страница 25: ...heuse l usine Le r glage ou la conversion des s cheuses sur le terrain pour des altitudes sup rieures 2 000 pi 610 m est effectu en changeant chaque orifice du br leur Si cette conversion est n cessai...

Страница 26: ...les raccordements pour la pr sence des fuites en appliquant une solution d eau savonneuse le d tergent liquide fonctionne bien RACCORD EN T DE 3 4 po x 1 2 po x 1 2 po 19 05 mm x 12 7 mm x 12 7 mm VO...

Страница 27: ...ns le sens antihoraire pour abaisser la pression REMARQUE La pression de sortie est mesur e pendant que le br leur est en marche pour toutes les conditions de r glage du br leur Par cons quent une foi...

Страница 28: ...fi s en cours de route ou en raison de conditions d emplacement marginales installation Mettre sous tension la s cheuse Voir les instructions d installation pour mettre la s cheuse en marche Ouvrir to...

Страница 29: ..._________________ R paration La r paration doit tre effectu e par un technicien ou une entreprise de r paration ayant les qualifications requises ou par le fournisseur de gaz Si une r paration est n c...

Страница 30: ...VEC DES ELEVATIONS ENTRE 610 A 1372M Assembled in Assemble aux USA Whirlpool Corporation TEL 269 923 3000 88 Currant Road FAX 508 678 9447 Fall River MA 02720 4781 mdl service whirlpool com WWW WHIRLP...

Страница 31: ...31...

Страница 32: ...WFR113543E 03 20 TM 2020 Maytag All rights reserved Tous droits r serv s...

Отзывы: